Specifications - Sony Artisan GDM-C520K Mode D'emploi

Masquer les pouces Voir aussi pour Artisan GDM-C520K:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications

Artisan™ Sensor
Test conditions
Accuracy
2
@85 cd/m
@5 cd/m
2
2
@.5 cd/m
Repeatability
Repeatability in this context is: same display, same sensor, and same environmental conditions (measured by the same standard)
2
@85 cd/m
2
@5 cd/m
2
@0.5 cd/m
Environmental Conditions
Operating Temperature
Relative Humidity
USB
Power Consumption
Artisan™ Signal Cable
Environmental Conditions
Operating Temperature
Relative Humidity
USB
Power Consumption
Reference-NIST certified reference
Ambient Temperature 24C +/- 2C
Display has been aged for >1 hour with a Full White field (85 cd/m2)
Display is calibrated to D50 (x = 0.346, y = 0.359, Y = 85 cd/m2)
Ambient light during calibration and measurement <2 lux
Signal timing--1152x870@70Hz
xy: +/- 0.002; Y: +/- 2%
<2 DeltaE deviation
<2 DeltaE deviation
xy: +/- 0.002; Y: +/- 1%
xy: +/- 0.006; Y: +/- 3%
xy: +/- 0.006; Y: +/- 3%
10 to 35 degrees C
20% to 80% non-condensing
v.1.0
5 Vdc +/-5%
20mA
10 to 35 degrees C
10% to 80% non-condensing
v.1.0
5 Vdc +/-5%
20mA
31