This appliance must be installed by a qualified electrician /
competent person gas safe register. Safety may be impaired if
installation is not carried out in accordance with these instructions.
This appliance shall be installed in accordance whit the regulations
in force and only in a well-ventilated space. Read the instructions
before installing or using this appliance.

IMPORTANT

We recommend to check wether the appliance has been foreseen
for the kind of gas distributed. Conversion for use other gases
must only be undertaken by a qualified person. For information
for use on other gases contact your local Service Centre. The
cooker must be installed by a qualified person, conforming to
local regulations. Failure to install the appliance correctly could
invalidate any manufacturers warranty and lead to prosecution
under the above quoted regulations.
Provision for Ventilation
The room containing the cooker should have an air supply in
accordance with local regulations.
Remember that the quantity of air necessary for combustion must
never be less than 2m3/h for each kW of power (see total power
in kW on the appliance data plate ).
Gas Safety (Installation & Use) Regulations
It is the law that all gas appliances are installed by competent
persons in accordance with the current edition of the Installation
& Use Regulations. It is in your interest and that of safety to
ensure compliance with the law.
The appliance must be installed in accordance with All relevant
British Standards (latest editions).
Gas Connection
Prior to installation, ensure that the local distribution conditions
(nature of the gas and gas pressure) and the adjustment conditions
are compatible. The adjustment conditions for this appliance are
stated on the rating plate which can be found on the back cover.
This appliance is not designed to be connected to a combustion
products evacuation device. Particular attention should be given
to the relevant requirements regarding ventilation.
Connection to the cooker should be made with connection in
accordance with local regulations.
WARNING: connect the gas to the oven's gas supply line using
the supplied connector A (see figure 3)
Fig. 3
GAS CONNECTING
(G / ) - ISO 7-1
1
2
In order to guarantee that the cooker works safely and has a
moderate energy consumption and long service life, you must
ensure that the supply pressure corresponds to the values given
in table D.
If this is not the case, a special pressure regulator must be fitted
to the gas supply pipe in accordance with the relevant standards.
The cooker must be connected to the gas supply pipe such that
the cooker is not subjected to any kind of stress.
A special valve for routinely turning the gas supply on/off must be
installed between the gas inlet tube to the room and the hob, in
order to cut off the gas supply after cooking in the event of
accidents during cooking. This valve must be easily accessible
at all times and should be closed during long periods of no use.
The gas tube must be routed in such a way that it is not fed
through hot areas and does not come into contact with any hot
parts of the appliance, e.g. the underside of the hob. Tube
installation must be carried out in such a way as to ensure that
it runs freely and that it cannot come into contact with or be bent
by any movable parts in the kitchen, e.g. drawers.
Certain types of cookers can be set for sypply both on the right
and lefthand side. In this case it is sufficient to reverse the position
of the cad nipple reducer. At the end make sure than there is no
leakage of gas.
Stop
Warning: do not use flames to check any gas leakages.
Inlet

Publicité

loading

Ce manuel est également adapté pour:

Dcm 1090