Technical Data - SKF TIH L Mode D'emploi

Masquer les pouces Voir aussi pour TIH L:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
ЗАО "Берг АБ"

2.2 Technical data

Designations type
T
I
T
I
T
I
T
I
Tecnhnical data
Voltage (±10%)
Recommended line protection
Power consumption (maximum)
Temperature control
Probe type
Probe maximum temperature
Time mode
Power range
Demagnetisation
Overall dimensions with bearing
supports (w x d x h)
Area between supports
(width x height)
Coils diameter
Weight with bearing supports
Workpiece maximum weight
Maximum heating temperature
Standard yoke cross section:
100 x 100 mm (3,9 x 3,9 in)
8
(495) 727-22-72
H
L
H
L
H
L
H
L
promshop- biz@ya.ru
4
4
/
7
7
/
4
4
/
7
7
/
Operating area
Width
Height
(dm)
(dm)
MV: 400-460V / 50-60Hz
LV: 200-240V/50-60Hz
50 A fuse rating for MV execution
100 A for LV execution
MV: 20,0-23,0 kVA
LV: 20,0-24,0kVA
0-250 °C (32-482 °F); in steps of 1°
thermocouple, K type
250 °C (482 °F)
0-99,9 minutes; in steps of 0,1 minute 100-120
minutes; in steps of 1 minute
100 %- 50 %
automatic; residual magnetism <2A/cm
1 550 x 1 330 x 850 mm
(61 x 52,3 x 33,4 in) for TIH L44
425 x 492 mm (16,7 x 19,4 in) for TIH L44
725 x 792 mm (22,4 x 31,2 in) for TIH L77
175 mm (6,8 in) - for minimum workpiece bore
diameter of 185 mm (7,2 in)
324 kg (714 lbs) for TIH L44
415 kg (914 lbs) for TIH L77
Bearing: 1 200 kg (2 600 lbs)
Solid component: consult SKF
approx. 400 °C (752 °F)
For minimum bearing bore diameter of:
150 mm (5,9 in)
www.promshop.biz
M
V
M
V
L
V
L
V
Voltage
MV: 400-460V (Medium Voltage)
LV: 200-240V (Low Voltage)