Open
window
detection
Light
Open
flickering
window
detection
Time round
Time
Min: s
Min: s
00:00 - 01:00
0:00
01:00-11:00
1:00
6:00
11:00
Remarks
1、When the appliance stop heating, alarm 5s and fan keep working 30s, then stand
by, set temperature mode light flickering and LED display OF and flickering.
1.1Press
After restart, Open window detection start a new time round.
1.2Press
appliance stand by.
1、Open window detection only can be start up when appliance in heating
mode(can not start up when appliance is only fan working) or in set temperature
mode.
2、Press "
", Open window detection on, Open window detection off.
3、Temperature detection start up after 1 minute from Open window detection
start up.
Per 10 minutes(temperature slow down detection check point) as a round, in one
round, detect the temperature once every 5 minutes(temperature fast down
detection check point). Detail in the following table.
Description
Open window detection start up
Temperature detection start up
Temperature detection starting check point
Temperature detection check point 1 (temperature fast down
detection check point).
1、Temperature detection check point 1 reduce from
Temperature detection starting check point ≤8℃, the appliance
keep heating and Open window detection keep working.
2、Temperature detection check point 1
reduce from Temperature detection starting check point > 8℃.
The appliance stop heating and stand by, Open window
detection stop.(See Remarks)
3、Temperature detection check point 1(**℃) ≥
Temperature detection starting check point, the appliance keep
heating and Open window detection keep working
**℃: Maximum detection temperature 51℃(See power-off
protection)
Temperature detection check point 2(temperature slow down
detection check point)
1、Temperature at this point is end of this round and start of
next round.
2、Per 10 minutes as a round, in one round, detect the
temperature once every 5 minutes
3、At Temperature detection check point 2, test method is the
same as Temperature detection check point 1.(compare with
Temperature detection starting check point)
to restart to the same working mode before the appliance stop.
to turn off, then LED display Environment temperature and the
28