Automatic Mode
In automatic extraction mode, the extraction level automatically adapts to the use of the cooking
zones.
1. Press the button.
2. To deactivate this mode, press again or use the slider.
Grease lter saturation warning
After 30 hours of hood operation, the symbol
grease lters. This alarm inhibits the suction operation until reset, to allow the water collection tray to be
emptied. (This operation must be carried out as needed and in any case must be done at each lter reset).
To reset this warning, press the button for 3 seconds
Odor lter saturation warning
After 120 hours of hood operation, the symbol
replace the active carbon
To reset this warning, press the button for 3 seconds
Maintenance Mode:
When maintenance mode is activated, the extraction ap will automatically open without turning
on the motor, allowing access to the extraction area and the compartments for the grease and
odor lters, so that cleaning and maintenance operations can be carried out.
To activate maintenance mode, press and hold the button for 3 seconds.
3
sec.
To exit maintenance mode, switch o the appliance by pressing the power button.
Note: The extraction continues to operate even when the cooking zones are paused.