SHRINK TUNNEL
OPERATING ISSUE
Conveyor not working.
No air flow.
PAGE 1 OF 3
1-800-295-5510
uline.com
TROUBLESHOOTING
CAUSES
Machine not powered correctly.
Bad fuse.
Pour le français, consulter la page 3.
RECOMMENDATIONS
Check power switch is ON and power cord is
plugged into or wired to power.
Check that main power is ON.
Check fuse: Remove Top Panel (12 screws).
Check fuse (F5 1 Amp fuse) between wires 11 and
16. Check fuse with fuse tester or multi-meter.
Replace fuse if bad.
Check fuse: Remove top panel (12 screws).
Check fuse (F1 20 Amp fuse) betweeen wires 4
and 6. Check fuse with fuse tester or
multi-meter. Replace fuse if bad.
Para Español, vea página 2.
0325 TH-951
loading

Sommaire des Matières pour Uline H-951

  • Page 1 Para Español, vea página 2. Pour le français, consulter la page 3. H-951 1-800-295-5510 uline.com SHRINK TUNNEL TROUBLESHOOTING OPERATING ISSUE CAUSES RECOMMENDATIONS Conveyor not working. Machine not powered correctly. Check power switch is ON and power cord is plugged into or wired to power.
  • Page 2 H-951 800-295-5510 uline.mx TÚNEL TERMOENCOGIBLE SOLUCIÓN DE PROBLEMAS PROBLEMA DE OPERACIÓN CAUSAS RECOMENDACIONES La banda transportadora no La maquina no enciende Verifique que el interruptor esté funciona. correctamente. encendido y que el cable de alimentación esté enchufado o conectado a la corriente eléctrica.
  • Page 3 H-951 1 800 295-5510 uline.ca TUNNEL DE RÉTRACTION DÉPANNAGE PROBLÈME DE FONCTIONNEMENT CAUSES RECOMMANDATIONS Le convoyeur ne fonctionne pas. La machine n'est pas Vérifiez que l'interrupteur d'alimentation est alimentée correctement. allumé et que le cordon d'alimentation est branché ou câblé à une source de courant.