Care And Maintenance; Corrective Action - Allen + Roth Lws1176E Mode D'emploi

Table des Matières
ASSEMBLY INSTRUCTIONS
12. Attach ground fixture wire to either the green
ground screw (AA) on crossbar (FF) or to the
ground wire in the outlet box (usually GREEN
or BARE). If attaching fixture ground wire to
the crossbar (FF), it is imperative the outlet
box in your home be properly grounded.
Connect the neutral WHITE or RIBBED side
fixture wire to the neutral usually WHITE wire
from the outlet box. Connect the hot BLACK
or SMOOTH side fixture wire to the hot
usually BLACK wire from the outlet box.
Fasten wires together with a wire
connector (BB) and tightly wrap wire connector
(BB) with electrical tape (not included).
Hardware Used
Green
Ground
AA
Screw
Wire
BB
Connector

CARE AND MAINTENANCE

• Wipe clean using soft, dry cloth or static duster. Always avoid using harsh chemicals and abrasives
to clean fixture as they may damage the finish.
TROUBLESHOOTING
PROBLEM
Bulbs will not light.
Fuse blows or the
circuit breaker trips
when light is turned
on.
x 1
x 3
POSSIBLE CAUSE
1. Bulb is burned out.
2. Power is off.
3. Faulty wire connection.
4. Faulty switch.
Crossed wires or power wire is
grounding out.
12
White Wire
From Outlet Box
Black Wire
From Outlet Box
Bare, or Green
Ground Wire
From Outlet Box
Bare, or Green
Ground Wire
From Outlet Box

CORRECTIVE ACTION

1. Replace light bulb.
2. Make sure power supply is on.
3. Check wiring.
4. Test or replace the switch.
Check wire connection.
Lowes.com/allenandroth
9
BB
White or
Ribbed Side
From Fixture
Black or
Smooth Side
From Fixture
Bare, or Green
Fixture Ground Wire
AA
OR