Environmental Conditions

Accuracy is given as ±(% of reading + counts of least significant
digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H.,
and is specified for 1 year after calibration.
Temperature Coefficient:
0.2 * (Specified accuracy) / °C, < 18°C, > 28°C
Operating Temperature:
● 0°C to 30 °C (≤ 80% R.H.)
● 30°C to 40 °C (≤ 75% R.H.)
● 40°C to 50 °C (≤ 45% R.H.)
Storage Temperature: -20°C to 60 °C (≤ 80% R.H., no batteries)
● Operating Altitude: 2000m (6562 ft)
● Shock: 4 feet drop per EN 61010-1
● Vibration: Random Vibration per MIL-PRF-28800F Class 2
● EN61326-1
Specification
Fuse DC Current Measurement
Fuse Type
MINI
(2A to 30A)
ATC/ATO
(1A to 40A)
MAXI
(20A to 80A)
Accuracy is based on the following condition, does not include
the accuracy of the fuse and the deviation of the fuse when
applying a current on it.
Fuse Type
MINI 30A
ATC/ATO 30A
MAXI 30A
Resolution
0.01A
0.01A
0.01A
Measured Standard
Voltage
18.50mV
39.40mV
58.50mV
6
EN
Accuracy
± (3% + 5D)
± (3% + 5D)
± (3% + 5D)
Display Result
10.00A
20.00A
30.00A