KCPROXWLC
Stainless Steel Proximity Card Reader & Keypad
4] PROGRAMMING CHART
2 beeps are emitted
Red
LED ON
Programming
illumination
keypad
A0
1 beep
Green LED ON
Enter:
- The illumination
time in seconds or
"00" for a permanent
illumination.
Default
= 10 sec
1 beep = OK
Green LED ON
4 beeps = Error
4
To program the keypad,
connect the blue cable with
the black cable.
Switch the power supply off
then switch it back on.
Programming
the code lenght
A2
1 beep
Green LED ON
Enter:
- 4, 5 or 6 to specify
the number of digits.
Default
= 5
1 beep = OK
Green LED ON
4 beeps = Error
EN
Programming the
Bit format
A3
1 beep
Green LED ON
Enter:
- 26, 30 or 44
to define the Bit
number of the
Wiegand format
Default
= 26
1 beep = OK
Green LED ON
4 beeps = Error