Operating Instructions; Cure Stamp Impressions - Trodat DRYTEQ Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6 Operating instructions

The dryteq UV exposure device has two exposure
modes:
• 2 sec mode for stamp impressions
20x20 mm bis 20x60 mm is preset.
• 0.5 sec mode for stamp impressions
up to 20x20 mm can be activated.

6.1 Cure stamp impressions

6.1.1 Impressions of 20x20 mm to 20x60 mm
Note
The surfaces to be stamped must be clean,
dry, dust-free and free of grease.
1. Stamp an impression in the desired place.
2. Turn on the UV exposure unit with the on/off
switch (ready for use after 10 seconds).
The 2-second mode is active. The maximum
exposure time is 2 seconds.
Battery status light glows:
• Green with a full battery charge (100%)
• Yellow with a half battery charge (50%)
• Red with a low battery charge (10%)
• When the battery is dead (0%), the battery status
will flash red. You must charge the device.
3. Position the UV exposure unit flush with the
fresh impression.
The narrow height of the stamp impression
must be covered.
4. Keep the push button pressed and move the
exposure unit sideways over the impression
for 2 seconds.