Installation Procedure - Toto CST412MF Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour CST412MF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

In order for your new TOTO toilet to fit correctly, please check the following dimensions:
1) Distance between finished wall and the center of the
floor drain, "RI", must be 12" (305mm) or 10" (254mm)
for CST412MF.10.
2) Water supply should be approximately 8" to 10" to
the left (facing the bowl) from the center line of closet
flange, and approximately 6" above the finished floor.
3) Using the provided template, confirm the installation
dimensions of the Socket or Modular Rough-In and the
mounting blocks.
Finished Wall
Supply
Valve
"RI"
1) Place the installation template so that the baseline of the template and the center line of the closet flange line up. Mark the screw loca-
tions for the Socket or
Modular Rough-In
case of tile or concrete floor installation, use the provided plastic anchors.
With the location properly marked, drill holes.
For wood floor installation:
• 3/32" for Socket or Modular Rough-In
• 11⁄64" for Mounting Blocks
2) Clean any debris out of the closet flange, then install the mounting bolts
into the slot of the flange head down with the threaded shank of the bolt
pointed upward as shown (Ill. 1). Slide each bolt until the end of slot.
3) Turn the Socket or
Modular Rough-In
seal onto the circular recess around the outlet opening. Turn the Socket
or
upright and lower it onto the position over the closet
Modular Rough-In
flange. With the unit properly aligned, press down firmly to set the wax seal.
Do not move the Socket/Modular Rough-In after wax seal is set.
CAUTION
4) Install a washer and nut on the T-bolt to secure the Socket or
to the flange (see Ill. 2). Nut should be tightened 1/2 turn after
Rough-In
hand-tightening. For the Modular Rough-In, secure the back side to the
floor using the provided screws until level. DO NOT USE EXCESSIVE
FORCE. Install the mounting blocks using the provided screws, washers,
and anchors. Ensure that blocks are firmly connected to the floor. Use the
provided template for the proper alignment.
To prevent water and odor leakage, please ensure that
the wax seal is fitted properly between the Socket or
CAUTION
Modular Rough-In and the flange. Do not overtighten
the nuts, as damage to the plastic parts may result.
5) The tank mounting hardware is included in the tank. Remove the warning
sticker from the bowl. Install the mounting hardware to the bowl as shown
(see Ill. 4). The mounting hardware is included in the TS810DV2 bag.
6) Place the toilet bowl over the Socket and
mounting blocks. For model CT414, put the
outlet of the toilet bowl to the mouth of the
then slide the toilet bowl
Modular Rough-In,
into socket gasket and over the Modular
Rough-In and mounting blocks until it
reaches the wall (see Ill. 5).
In order to prevent leakage,
be sure to insert the toilet all
CAUTION
the way into position.
Before Installation (continued)
C/L
Closet
Flange

INSTALLATION PROCEDURE

and mounting blocks. Drill holes at the marked locations per the installation type below. In the
For concrete/tile installation:
• 9 ⁄32" for Socket or Modular Rough-In using green
anchors
• 1 1⁄32" for Mounting Block using white anchors
upside down. Firmly press a new wax
Ill. 4
B
6-3/8"
(160mm)
CST414 only
6" (152mm)
Ill. 2
Modular
Ill. 3
Ill. 5
3
MODEL
A
B
3-3/8"
7-7/8"
CST412/416
( 85mm)
(200mm)
1-3/4"
7-7/8"
CST412.10
(45mm)
(200mm)
3-3/8"
8-1/2"
CST464
(85mm)
(215mm)
2-1/2"
7-1/2"
CST414
(63mm)
(190mm)
Ill. 1
Joint
not included
(non inclus)
*CST412
CST416
*CST414
CST464
Rough in
Rough in

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Cst412mf.10Cst414mCst416mCst464mf

Table des Matières