Disposal
Dispose of the unit in accordance with the national legal regulations.
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.

Technical data

Description
Input data (Pri)
Input voltage range
Max. input current
Starting current for 2 ms at full load and 230 V AC
Input frequency range
Power consumption in standby
Output data
Output voltage range
(Sec)
Max. output current
(no limitation per output)
Max. power output
Max. starting current, secondary side for max. 4 ms
Maximum output/peak power? for max. 4 ms
Residual ripple
Setup time at 115/230 V AC
Rise time at 115/230 V AC
Hold-up time at 115/230 V AC
Efficiency
(at rated mains voltage 230 V AC and max. output current)
Power factor
Protection class
Isolation between the primary/secondary side
Overvoltage protection (Sec), power pack switches off at
Overload protection (derating)
Reset duration after triggering of the overload protection / overvoltage protection
High voltage test
Test voltage between Pri and Sec
Test voltage between Pri and PE
Test voltage between Sec and PE
Insulation resistance between L/N and PE at 500 V AC
Standards complied with
Maximum submersion depth
Permissible water temperature
operation in water, product active
Permissible water temperature
operation in water, product inactive
Permissible ambient temperature
operation outside the water, product active
Permissible storage temperature
(product inactive = disconnected from the power supply)
Length of power cable
Dimensions
Length
Width
Height
Weight
Article number
The values were determined after an operating time of 15 minutes and an ambient temperature of +20 °C.
1)
14
1)
1)
1)
1)
1)
Underwater Power Supply 250
V AC
90 ... 264
A
A
Hz
47 ... 63
W
V DC
24.25 ... 25.75
A
W
A
W
%
≤1 (U
pp
ms
ms
ms
≥0.92
galvanic
V
(→ Derating characteristic curve)
Min
kV AC
kV AC
kV AC
MΩ
EN 61558-1:2005+A1:2009
EN 61558-2-16 + A1:2013
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
m
°C
+4 ... +35
°C
+4 ... +35
°C
-10 ... +40
°C
-20 ... +70
m
mm
mm
mm
kg
50733
3.5
40
<7
10
250
15
364
≤ 250 mV)
<100
<30
>10
≥0.9
IP 68
≤33
5
≥4
≥1.5
≥500
>2
4
10
260
162
77
5.3