Ganz GH-Fast Série Manuel D'installation page 5

Caisson extérieur
Masquer les pouces Voir aussi pour GH-Fast Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
FUN installation
Please note that housing heater must be connected only to
appropriate power supply sources as previously indicated in this
manual.
All outdoor GH-F housings are provided with a power distribution
board; if you need to install a GH-B12 fun, you need to substitute
this board with the once coming with the fun and you must provide
a stabilized (12VDC ±5%) power supply source.
Follow these steps:
1.
Open the housing like above indicated.
2.
Connect fun "JP1"terminal to AUX terminals of distribution
power supply board
3.
connect the camera power conductors to "OUTPUT"
terminals of distribution power supply board.
4.
Connect the main power supply input conductors to
appropriate "INPUT" terminals of distribution power board.
5.
Connect "HEATER" terminals of distribution power board to
heater power supply conductors.
6.
Fix the fun board on spacers located on upper part of the
housing.
In case you have not bought a pre-cabled version of GH-F housing,
the power supply line have to be provided by a three conductors
cable running through the central PG11 gland inside of the housing
or by the appropriate rubber provided for hidden cabling running
(see Hidden cable protection connection): the main power supply
conductors have to be connected to the appropriate terminal strips
in the following way:
Meaning
Conductors color
MainPower IN
Blue/Brown
Out Heater
White
Out Camera
Out Fun
In addition, crimp the ground conductor to a ring terminal and fix it
to the point identified by Ground symbol by the M4 screw provided
on standard distribution board.
In case of 12VDC models, use pin n°1 as
positive(+12V) and pin n°2 as negative (0V).
ZVA-TW100T/GH installation (only 230V~ versions)
Please note that housing heater must be connected only to
appropriate power supply sources as previously indicated in this
manual.
Follow these steps:
1.
Open the housing like above indicated.
2.
Connect "AUX" terminals of distribution power supply board
to the ZVA-TW100T/GH "230V~" terminals
3.
connect the camera power conductors to "OUTPUT"
terminals of distribution power supply board in parallel.
4.
Execute all remaining connections following indications of
ZVA-TW100T/GH manual.
5.
Connect the main power supply input conductors to
appropriate "INPUT" terminals of distribution power board.
6.
Fix the board on spacers located on bottom part of the
housing.
In case you have not bought a pre-cabled version of GH-F housing,
the power supply line have to be provided by a three conductors
cable running through the central PG11 gland inside of the housing
or by the appropriate rubber provided for hidden cabling running
(see Hidden cable protection connection): the main power supply
conductors have to be connected to the appropriate terminal strips
in the following way:
Meaning
Conductors color
MainPower IN
Blue/Brown
Out Heater
White
Out Camera
ZVA-TW100T/GH
In addition, crimp the ground conductor to a ring terminal and fix it
to the point identified by Ground symbol by the M4 screw provided
on standard distribution board.
GH-VTA installation
This device does not need any additional power supply; please fit
tamper and GH-VTA-T into their appropriate bays located in back
part of the housing (see FIG.5).
External connections
In case you have not bought a pre-cabled version of GH-F housing,
you will need to run a RG-59/U cable through one of the side
glands PG9, crimp it and connect to the camera. Verify the proper
water seal of the gland.
In case you need auxiliary connection cabling with camera station
(for example motorized zoom, tamper sensors, camera serial port),
run a multiconductors cable by one of the PG9 gland inside of the
housing.
Note that to open the PG shape, you need to force it using a screw
driver from outside part of the housing (see FIG.6)
\
Terminal strip
INPUT
HEATER
OUTPUT
AUX
Terminal strip
INPUT
HEATER
OUTPUT
AUX
5
Hidden cable protection connection
Also easy hidden cable protection is available following four quick
steps (see FIG.8):
1.
force the hidden cabling shape, in the middle of the
housing, with a screw driver from outside part of the
housing.
2.
properly fix bracket to the wall after having inserted cables
3.
run cables inside adjustable head and fix it to the bracket
4.
Insert cables in conic rubber, please note that only two
halls are opened by default and that you need to open the
third one in case you want to use additional cables.
5.
fix housing on adjustable head only with provided screws
6.
rubber will be automatically pressed on housing body
guaranteeing IP66 protection.
Please use only appropriate cables.
ENCLOSURE ASSEMBLY
Housing re-assembly
If this will be the latest operation to complete the housing body
closure, insert the desiccant bag (without plastic protection) inside
of the body before to proceed.
Close top body of the housing and fix it by the two opened swivel
spindles. Please turn the two safety screws for 90° matching locker
symbol and taking care that no cables are improperly running out
the housing.
Please assure all cables are correctly running inside the housing
before to close it and to not force housing to be closed.
Sunshield adjust
Sunshield can be moved to different positions unscrewing it. Please
note that you can find two additional shapes in the internal part of
the sunshield that you can drill to achieve an additional sunshield
excursion (see FIG.8).
Fixing of sunshield
Re-positioning of the sunshield on the holding points.
Insert the fixing screws and tie.
NOTES: every time you will open the housing, to avoid any
condensation effect, please change the desiccant bag with
a new one.
FIXING THE CAMERA STATION
The GH-F housing series is a light and medium/small enclosure for
CCTV camera/lens outdoor application. Nevertheless, especially
outdoor application can face severe environmental condition like
strong wind, heavy snow and ice in addition to a suitable load
bearing.
This require to the installer the maximum and careful attention on
fixing the camera station in the proper and safety way.
For example, to fix a camera station using GH-F housing series
with its own adjustable head and bracket on a wall, we suggest you
to use (4) steel fasteners with 12 mm external diameter and M6 bolt
with 10mm head.
Use as drilling mask a photocopy 1:1 of the latest page of this
manual reporting the bracket and cable running holes layout
positioning.
NOTES
GH-F housing provides two frontal screw threads for easy and
comfortable accessories installation (ex. IR lamps) and an
additional round shape that could be used for additional hidden
cabling or installation of air-filter (see FIG.9).
In case you need lateral bracket cabling, you can operate as
indicated in FIG.10.
Use only neoprene outdoor cables to guarantee IP66
protection rate: Video RG59 Ø6,1 mm, Alimentation Ø7 mm
(3x1 mmq)
Lock safely high voltage cables and properly separate them by
low voltage ones
When used/requested, cut ground cable longer than phase and
neutral
This housing must not be considered a FIRE-ENCLOSURE; all
installed equipments must be compliant to EN 60950-1.
PLEASE DO NOT CLEAN FRONTAL WINDOW WITH ANY
CHEMICAL PRODUCT; PLEASE USE ONLY WATER
TECHNICAL SPECIFICATIONS
Consumption:
GH-F230:
GH-F24:
GH-F12:
Maximum internal load:
IPrate:
Operating Temperature:
Storage Temperature:
Vandal resistance:
Fire-self extinguish:
Rev.18/04/2013
< 40 mA
< 350 mA
< 700 mA
20W (-20°C ~50°C)
IP 66 (hidden or external cabling)
-20°C to +55°C (Max.internal load 17W)
-30°C to +55°C, RH 85% not
condensing
IK10 according to EN50102
V2 fire-self extinguish according
to UL94

Publicité

Table des Matières
loading

Table des Matières