Function/Range Switch Instruction
Switch Position
Input Terminal Instruction
The terminals are indicated in Figure 2, and explained in Table 2.
Item
Description
Test voltage output terminal in insulation test.
Test current input terminal in insulation test. Input terminal for current measurements < 400mA.
An optional shield terminal in insulation test. Common (return) terminal for all measurements except
insulation test.
Input terminal for voltage, continuity, resistance, diode and frequency measurements.
Measurement Function
AC voltage from 0V to 600V.
DC voltage from 0V to 600V.
Ohms from 0Ω to 40MΩ .
Diode test. Displays "0L" above 2V.
Continuity test. Buzzer turns on at < 30Ω and turns off at > 50Ω .
Frequency from 1Hz to 100kHz
DC mA from 0mA to 400mA.
AC mA from 0mA to 400mA.
MegOhms from 0.1MΩ to 4000MΩ, and test voltage is 250V.
MegOhms from 0.1MΩ to 4000MΩ, and test voltage is 500V.
MegOhms from 0.1MΩ to 4000MΩ, and test voltage is 1000V.