Water filter data

SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005
Specifications
Service Flow Rate (maximum) ...............................................0.75 GPM (2.83 L/min)
Rated Service Life Model 9005 (maximum)...........................500 gallons/1892 liters
Maximum Operating Temperature..........................................100° F/38° C
Minimum Operating Temperature...........................................33° F/1° C
Minimum Pressure Requirement............................................35 psi/138 kPa
Maximum Operating Pressure ...............................................120 psi/827 kPa
PERFORMANCE DATA
Influent Challenge
Substance
Concentration
Lead
0.15 mg/L +/- 10%
Lead
0.15 mg/L +/- 10%
Cyst
Minimum 50,000/L
Turbidity
11+/-1 NTU
Lindane
0.002 mg/L +/- 10%
Atrazine
0.009 mg/L +/- 10%
Chlorine
2.0 mg/L +/- 10%
Particulate**
at least 10,000
particles/mL
2,4-D
0.210 mg/L +/- 10%
Asbestos
10
to 10
fibers/L; fibers greater
7
8
than 10 micrometers in length
* Tested using a flow rate of 0.75 GPM (2.83 L/min.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 –1 microns.
Effluent
Average %
Maximum
Average
Reduction
Effluent
0.001 mg/L
99.33%
0.001 mg/L
0.002 mg/L
98.66%
0.003 mg/L
1count/mL
99.99%
3 count/mL
0.12 NTU
98.98%
0.18 NTU
0.00005 mg/L
97.62%
0.00005 mg/L
0.0002 mg/L
97.93%
0.0006 mg/L
0.09 mg/L
95.26%
0.17 mg/L
900 count/mL
99.68%
2400 count/mL
45.45 ug/L
84.42%
100 ug/L
0.16 MFL/mL
99.96%
0.16 MFL/mL
1000 Apollo Road
Eagan, Minnesota U.S.A.
EPA EST #35917-MN-1
GENERAL USE
CONDITIONS
Read this Performance Data Sheet and
compare the capabilities of this
refrigerator with your actual water
treatment needs.
DO NOT use this product where water
is microbiologically unsafe or of
unknown quality without adequate
disinfection installed before or after
filtration system. Systems certified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Min. Required Inlet
Check for compliance with the state
Reduction
pH
and local laws and regulations.
0.010 mg/L
6.5
The retractable water filtration system
0.010 mg/L
8.5
uses a 9005 replacement cartridge (see
> 99.95%
NA
Sears contact information at the back of
0.5 NTU
NA
your Use and Care Guide to order).
0.00002 mg/L
NA
Timely replacement of filter cartridge is
0.003 mg/L
NA
essential for performance satisfaction
≥75%
NA
from this filtration system. Please refer
≥85%
NA
to the applicable section in this Use and
Care Guide for general operation,
0.0017 mg/L
NA
maintenance requirements and
99%
NA
troubleshooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentration of the indicated
substances in water entering the system
was reduced to a concentration less than
or equal to the permissible limit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-KNI300 and WF50-KWI500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction