De Dietrich DTV301 3,4 kW Série Guide D'utilisation Et D'installation page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

99627093_ML.qxd
02/03/04
Connection
These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with
publication CEI 60083 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged, it must be replaced by the manufacturers, their After Sales Service or another
similarly qualified person for avoiding any possible risk of accident.
When connected to 400 V2N three-phase, if you hob malfunctions, check that the neutral cable is pro-
perly connected.
The unit must be installed so that the mains plug is easily accessible.
- 220-240 V monophase
fuse : 32 amp
Blue
Brown
L
N
fuse : 16 Amp
Blue
Brown
10:11
Page 15
Installing your hob in complete safety
Green/yellow
Brown
Blue
Black
Green/yellow
15
- 400- V 2N three-phase
fuse : 16 Amp
Green/yellow
Black
NOTE
Separate the 2
phase wires L1
and L2 before
N L1
L2
connecting
220-240 V∼ ∼ 50-60 Hz
Total energy consumption:
DTV301.......3,4 kW
DTV303.......7 kW
DTV304.......6,2 kW
DTV305.......6,9 kW
DTV306.......7 kW

Publicité

Table des Matières
loading

Table des Matières