1. CHARACTERISTICS
Left/right opening function electric lock.
Works on 8 – 12 V~ continuous or alternating current (transformer ref. WETR 14602 SER.R1).
Reduced power consumption:
700 mA at 12 V~
500 mA at 8 V~
Voltage: 12-V ~ or
Important: Terminal wire calibre:
• 1-25 metres: 2 x 6/10 wires,
• over 25 metres: 2 x1.5 mm2 wires (the whole length).
2. INSTALLATION
The lock is supplied "right" mounted. To change it to a "left" mounting:
• Swing the lock around on its metal carrier.
• Change over the two rubber covers to position the cable hole downwards (A).
a. attachment of the electric lock (Fig 2)
• Determine the position of the stirrup and the cylinder hole with the template.
• Using the four screws (B) supplied, fix the carrier to the gate.
• Using the four screws (C), fix the electric lock to the carrier.
• Close the electric lock housing back up using the two screws (D).
b. fixing the keeper (Fig 3)
• Fix the keeper using the three screws (E) supplied according to the height stipulated in the template.

3. ELECTRICAL CONNECTIONS

(Fig 1)
• Pass the cables through the correct hole (A).
• Loosen the two screws (1, Fig 1).
• Fix the first wire between the two small plates.
• Do the same with the second wire (ignore the polarity).
Important: This type of lock cannot be used on outward-opening gates. Leave a space of about 9 millimetres
between the keeper and the lock (F, Fig 4). During a power cut, the key can always be used so there is never any
problem getting back in.
If you want to test your lock before it is installed, the presence of the keeper must always be simulated by pressing
on the memorisation flap (2 , Fig. 1) to activate the mechanical memory.
4. MECHANICAL UNLOCKING
The push-button mechanism is enabled by the keyed cylinder only. Unlock to confirm, lock to bar access.