WMM30 Product HANDBOOK
Input Parameters:
Description
Nominal input voltage
Input voltage range
Nominal Input frequency
Maximum input current
* If the WMM30CN is operated between 90-80VAC the output current is to be derated 1% per Volt from
90Vac.
Input Connections:
AC input plug: EU example shown.
(Note: AC input plugs for Europe, United Kingdom, North America & Australia
are sold separately)
Part number
Region
ACC-WMM30-A North America
ACC-WMM30-U UK
ACC-WMM30-E Europe
ACC-WMM30-A Australia
Locating AC Plug option.
1. Locate tabs A and B in the runners as shown.
2. Slide the plug firmly towards the rear of the locating plate until latch C locks the plug in place – latch
highlighted in red.
Operation
100-240VAC
80-264VAC*
50-60Hz
0.8A@80VAC
Page 14 of 16