NOTE
2-1. Specifications
Input
Rated Welding
Power
Power
Output
Output
450 A @ 38 Volts DC, 100%
Three
Duty Cycle;
Phase
565 A @ 43 Volts DC,
60% Duty Cycle
*While idling
2-2. Duty Cycle and Overheating
100% Duty Cycle At 450 Amperes
Continuous Welding
Overheating
SECTION 2 – INSTALLATION
Unless otherwise noted, the Invision 456P is shown throughout this manual.
Amperage
Range
Voltage
(Phoenix
Range
Range
456 CC/
456 CC/
CV Only)
5 – 600
10 – 38
0
Minutes
Amperes Input At Rated
Maximum
Load Output 60 Hz,
Open-Circuit
Three-Phase
Voltage DC
Voltage DC
95
60% Duty Cycle At 565 Amperes
6 Minutes Welding
15
OR
Reduce Duty Cycle
575 V
KVA
24.4
24.3
(0.12*)
(0.12*)
Duty Cycle is percentage of 10
minutes that unit can weld at rated
load without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
duty cycle before welding.
Exceeding duty cycle can
damage unit and void war-
ranty.
4 Minutes Resting
A/V
duty1 4/95 – SA-181 560
OM-186 989 Page 9
KW
19.0
(0.07*)