Urmet 1051 Série Guide Rapide page 5

Détecteur double infrarouge avec fonction pet d'extérieur camera integree
Masquer les pouces Voir aussi pour 1051 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
1.
Sun shield
2.
Camera lens
3.
IR sensor lenses
4.
Red LED/Function button
5.
Illuminator
6.
Battery compartment cover
7.
Tamper switch
8.
Battery compartment
9.
Dip switch block
10. Bracket arm
11. Rotation bracket
LED
The red LED lights up in the following conditions:
-
The red LED flashes once every 20 minutes: The detector has lost its connection with the control unit.
-
The red LED lights up for 30 seconds: The detector is being initialised and a fault was detected.
-
The red LED flashes quickly twice: The detector is connected correctly to the control unit after the learning procedure.
-
The red LED lights up for two seconds during normal operation: The detector has detected motion and a fault was detected.
-
The red LED flashes quickly: The detector is transmitting images to the control unit and a fault was detected.
-
The red LED and illuminator flash once: The detector was restored.
Using the function button:
Press the button once to send a supervision signal. To reset the detector: hold the button pressed for 10 seconds. Release the button
when the illuminator and the red LED blink once.
DIP Switch position table
Position the dip switches according to the place of installation of the detector and the pet immunity requirements.
The function of each dip switch is listed in the following table. The dip switches can be ON or OFF. Position up indicates ON,
position down indicates OFF.
DIP
Position
Function
ON
Switch1
OFF
ON
Switch2
OFF
ON
Switch3
OFF
ON
Switch4
OFF
Learning procedure
The detector must be learnt by the control unit to transmit the signal if motion is detected. Proceed as follows to perform the device
learning procedure. The detector may be learnt by the control unit only within three minutes from switch-on.
1.
Remove the sun visor fastening screws to remove this component.
2.
Remove the battery compartment cover to open the battery compartment and the dip switches.
3.
If necessary, configure the dip switches; for information on setting, see the table provided above.
DS1051-033
Disable rest time
Enable rest time (default)
Reserved
Detector facing a closed space (eg a wall
higher than a person within 10 m of the
detector)
Detector facing an open space (no wall
within 10 m of the detector) (default)
Detector facing a surface that does not
easily release heat (eg a lawn) (default)
Detector facing a surface that easily
releases heat (eg in cement, or stone or
tiled)
Detection chart
DIP
Switch5
ON
ON
OFF
OFF
DIP
Switch7
Switch8
Sensitivity level
Switch6
ON
Low; for 75 cm / 60 kg animals
Medium; for 60 cm / 40 kg
OFF
animals
ON
High; for 45 cm / 30 kg animals
:
Maximum
for
OFF
animals (default)
Position
Function
ON
Enable double detection (default)
OFF
Disable double detection
ON
Reserved
OFF
30
cm/20
kg
5