W.E. Anderson FlotecT L6 Installation Et Mode D'emploi

Masquer les pouces Voir aussi pour FlotecT L6:
Les langues disponibles

Les langues disponibles

Explosion-Proof; UL and CSA Listed -
Class I, Groups *A, B, C, & D
Class II, Groups E, F & G
Directive 2014/34/EU (ATEX) Compliant for
2813
II 2 G Ex db IIC T6 Gb Process Temp≤75°C
IECEx Compliant for Ex db IIC T6 Gb Process Temp≤75°C
*(Group A, stainless steel body only)
DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
Model L6
Specifications - Installation and Operating Instructions
SPECIFICATIONS
Service: Liquids compatible with wetted materials.
Wetted Materials: Float: Solid polypropylene or 304 SS; Lower Body: Brass or
303 SS; Magnet: Ceramic; External Float Chamber (Tee): Matches lower body
choice of brass or 303 SS; Other: Lever Arm, Spring, Pin, etc.: 301 SS.
Temperature Limit: -4 to 220°F (-20 to 105°C) Standard, MT high temperature
option 400°F (205°C)(MT not UL, CSA, ATEX, IECEx and KC). ATEX compliant
AT, IECEx IEC and KC option ambient temperature -4 to 167°F (-20 to 75°C)
process temperature: -4 to 220°F (-20 to 105°C).
Pressure Limits: See next page.
Enclosure Rating: Weatherproof and Explosion-proof. Listed with UL and CSA
for Class I, Groups A, B, C and D; Class II, Groups E, F, and G. (Group A on stain-
less steel body models only).
EU-Type Certificate No.: KEMA 04ATEX2128.
ATEX Standards: EN 60079-0: 2012 + A11: 2013; EN60079-1: 2014.
IECEx Certified: For Ex db IIC T6 Gb Process Temp≤ 75°C.
IECEx Certificate of Conformity: IECEx DEK II.0039.
IECEx Standards: IEC 60079-00: 2011; IEC 60079-1: 2014.
Korean Certified (KC) for Ex d IIC T6 Gb Process Temp≤75°C.
KTL Certificate Number: 12-KB4BO-0091.
Switch Type: SPDT snap switch standard, DPDT snap switch optional.
Electrical Rating: UL models: 5 A @ 125/250 VAC (V~). CSA, ATEX and IECEx
models: 5 A @ 125/250 VAC (V~); 5A res., 3 A ind. @ 30 VDC (V ). MV option:
0.1 A @ 125 VAC (V~). MT option: 5 A @125/250 VAC (V~). [MT option not UL,
CSA, ATEX or IECEx].
Electrical Connections: UL models: 18 AWG, 18˝ (460 mm) long.
ATEX/CSA/IECEx models: terminal block.
Upper Body: Brass or 303 SS.
Conduit Connection: 3/4˝ male NPT standard, 3/4˝ female NPT on junction box
models. M25 x 1.5 with - BSPT option.
Process Connection: 1˝ male NPT on models without external float chamber, 1˝
female NPT on models with external float chamber.
Mounting Orientation: Horizontal with index arrow pointing down.
Weight: Approximately 1 lb (.5 kg) without external float chamber, 1.75 lb (.8 kg)
with external float chamber.
Specific Gravity: See next page.
Float Switch
2813
II 2 G Ex db IIC T6 Gb Process Temp≤75°C.
Phone: 219-879-8000
Fax: 219-872-9057
Bulletin E-20
www.dwyer-inst.com
e-mail: info@dwyermail.com
Table des Matières
loading

Sommaire des Matières pour W.E. Anderson FlotecT L6

  • Page 5: Détecteur De Niveau

    Bulletin E-20 Détecteur de niveau Modèle L6 Spécifications - Installation et mode d’emploi Antidéflagration et étanche ; homologué UL et CSA- SPÉCIFICATIONS Utilisation : Gaz ou liquides compatibles avec les matériaux mouillés. Classe I, Groupes *A, B, C, et D Matériaux mouillés : Flotteur : en propylène expansé...
  • Page 6: Raccordements Électriques

    Exemple B0HB Série L6EPB-B-D-3-0-CSA-B0HB Flotect Détecteur de niveau de liquide, corps en ® laiton, DPDT, sphérique flotteur en polypropylène, montage mural, Approuvée par CSA, avec 1-1/2" type hex bague en laiton. Série Flotect ® Détecteur de niveau de liquide Fabrication Antidéflagation Corps Laiton...
  • Page 7: Entretien

    Tous les câbles, conduites et boîtiers doivent être conformes aux codes en vigueur TABLEAU DES MATÉRIAUX MOUILLÉS en matière de zones dangereuses. Les conduites et les boîtiers doivent être Acier Acier Acier correctement scellés. Pour les installations en extérieur ou emplacements où les Modèle Laito Bronze...
  • Page 8 Garantie limitée : Tous les instruments et équipements Dwyer sont garantis sans dé- Recours de l’acheteur : LE SEUL ET UNIQUE RECOURS DE L’ACHETEUR, DANS faut de fabrication par le vendeur et pour une période de un an à partir de la date d’en- LE CADRE D’UN OBJET NON CONFORME OU DÉFECTUEUX, EST LE voi, dans le cadre d’une utilisation et d’un entretien normaux.