Using The Appliance For The First Time - BIELMEIER BHG 558 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
Now secure the water filter (7) back in the
lid (8) and put the tank (2) back in place
again .
This completes the cleaning process .
4 The water filter (7) should be replaced every
6 – 12 month .
How to replace the filter (7):
Remove the tank (2), unscrew the lid (8) and
remove the water filter (7) .
Now secure the new water filter (7) in the
lid (8) and put the tank (2) back in place
again .
This completes replacement .
5 Please remove the water filter (7) and store
in a dry place with the appliance if the air hu-
midifier is not going to be used for a lengthy
period of time .
CARE RECoMMENDAtIoNS
Operate the air humidifier with distilled water
to prevent limescale .
Replace any unused water regularly to protect
it from contamination .
If the air humidifier is not going to be used for
a lengthy period of time, remove the water
filter  (7) (see "Cleaning and replacement of
water filter") . Leave the water tank (2) uncov-
ered to dry thoroughly and store the appliance
in a dry place .
Allow all parts of the air humidifier to dry before
packing it away .
USE oF CItRIC ACID oR otHER DESCALERS
Switch off the air humidifier and remove the
power plug (11) .
Drain off the water .
Add 5 –10 drops of descaler or 1 – 2 g of citric
acid to the recess in the appliance base (9) and
fill up with warm water (approx . 60° C) until
the water covers the white valve .
Then rinse out the recess in the appliance base
(9) with clean water .
12
USING tHE APPLIANCE
FoR tHE FIRSt tIME
1 Position the air humidifier at a suitable
location and remove the tank (2) .
Remove the lid (8) and fill the tank (2) with
water (tap water or distilled water) .
Recommendation: The use of distilled wa-
ter in the BHG 558 air humidifier will prevent
limescale .
2 Now put the lid (8) back on the tank (2) . Wipe
off any splashes of water on the outside of the
water tank (2) preferably using a soft cloth .
Place the tank (2) back on the appliance base
(9) .
3 Insert the power plug (220 – 240 V / 50 Hz) and
press the power switch (10) . You will hear a beep .
The air humidifier is now in Stand-by mode . The
Stand-by indicator (16) switches on .
4 Press the "EIN / AUS" (on/off) button (21) . The
Standby indicator (16) is extinguished, and the
mist setting S2 (red + orange) is displayed (18) .
The air humidifier is now in Continuous mode
(AUTO indicator (12) not lit up) and continu-
ously emits an atomised spray at level 2 .
The current relative air humidity in the envi-
ronment is displayed on the humidity indi-
cator  (13) .
5 Press the "Nebel" (mist) button (20) to adjust
the level of the atomised spray (18) .
There are four levels for selecting the density
of the mist produced:
S1 – S2 – S3 – S4
(red – orange – blue – green).
The indicator (18) displays the density of the
atomised spray just selected .
6 Automatic mode (12) aims to attain a specific
humidity level in the room .
To activate this mode, press the Humidity but-
ton (19) . AUTO (12) lights up, and the humidity
indicator (13) reads 40 % .
It is possible to select a relative humidity level
of 40 % – 70 % RF (relative humidity) for the
room air . Every time you tap on the selection
button (19), the humidity level selected will in-
crease by 1 % . If you press the selection button
slightly longer, the humidity level selected will
increase by 5 % .
After selection the humidity indicator  (13)
switches between the current / selected humi-
dity level every 5 seconds .
The appliance switches off automatically when
the humidity level in the room reaches the val-
ue set on the air humidifier . Humidification will
restart as soon as the humidity level falls again
in the room .
7 The operating time can be set from 1 – 12
hours . To do so press the "Dauer" (duration)
button  (22) . Each press of the button will add
an hour . The running time will start as soon as
selection ends .
The air humidifier switches off automatically
when the selected time expires .
8 If there is too little water in the tank, no spray
will be produced . You will hear a beep, and
the water level indicator (14) lights up . Please
switch the air humidifier off and fill up the tank
with water (2) (see items 1 and 2) .
If no water is added, the appliance will switch
off automatically after 1 minute .
GUIDE vALUES FoR RELAtIvE HUMIDItY
LEvELS IN RooMS DEPENDING oN tHEIR
FUNCtIoN
Closed rooms
Rel. humidity
at 20°C
(in %)
Living / work room
35 – 50
in summer
Living / work room
50 – 70
in winter
Offices
40 – 60
Caution: The humidity levels specified in these
instructions for use are only guide values .
GB
12
13
14
15
16
17
S1
S2
S3
S4
18
19
20
21
22
12 Display of automatic mode
13 Display of relative humidity
(in %)
14 Water tank empty
15 Operation indicator
16 Stand-by indicator
17 Display of operating time
(in hours)
18 Display of mist density:
Level 1 = S1 (red)
Level 2 = S2 (red + orange)
Level 3 = S3 (red + orange + blue)
Level 4 = S4 (red + orange + blue + green)
19 Selection of humidity level
20 Selection of mist density
21 On / off button
22 Selection of operating time
Fig. 1:
Display (3) and operator panel (4) in detail
13

Publicité

Table des Matières
loading

Table des Matières