POSSIBLE FAULTS, THEIR CAUSES AND SOLUTIONS
FAULTS
• The pump will not prime
• The pump provides a poor flow rate
• The pump makes a lot of noise
• The pump will not start
CAUSES
• The pump has not been primed
• Air entering by the suction piping
• Air entering via the mechanical seal
• Incorrectly closed pre-filter cover
• Excessive suction height
• Inverted motor rotation
• Incorrect voltage
• Air entering by the suction piping.
• Excessive suction height.
• Inverted motor rotation.
• Incorrect voltage.
• Blocked
• Suction piping diameter is less than
that required.
• Impulsion closed or blocked.
• Suction piping diameter is less than
that required.
• The pump or piping has not been
correctly secured.
• Inverted motor rotation
• Lack of mains supply.
• Breaker operation.
• Incorrect voltage.
• Motor jammed.
12
SOLUTIONS
• Fill the pre-filter with water.
• Check the connections and piping.
• Replace the mechanical seal.
• Close correctly.
• Install at a suitable height.
• Invert two of the motor phases.
• Check the plate voltage.
• Check the connections and piping.
• Install at a suitable height.
• Invert two of the motor phases.
• Check the plate voltage.
• Clean the pre-filter basket.
• Correctly dimension the suction piping.
• Open the valve and check the sand
filter condition.
• Correctly dimension the suction piping.
• Recheck the pump and piping securing
methods so that they are separate.
• Invert two of the motor phases
• Check the voltage and fuses.
• Check and reset breaker.
• Check the plate voltage.
• Consult the Official Technical Service.