Assembly And Installation - simatec simalube 30 Mode D'emploi

Masquer les pouces Voir aussi pour simalube 30:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN

Assembly and Installation

Security note: If the lubricator is started without opening the outlet or in case of
blocked grease lines within the installation, the pressure in the lubricator can build up
approx. 5 bar. At an overpressure of approx. 6 bar the lubricator breaks at the defined
breaking point between housing and bottom. The pressure behind the piston releases
and oil or grease can come out at the breaking point.
The correct functioning of the lubricator can only be assured if recommended lubricants
(see table on page 14) and original simalube accessories are used, and if the installa-
tion, operating and maintenance instructions are closely followed. The manufacturer
cannot accept any responsibility for damages as a result of ignoring the instructions
mentioned above. Important: Before putting simalube into operation fill extensions
and the lubrication lines with the appropriate simalube greases (cartouches SL01 ...SL26)
using a grease gun. Use only original accessories.
Temperature / Output rate
The output rate can be adjusted as required, depending on the ambient temperature
(see table).
Example: You want to set the dispensing time for a 125 ml simalube for 180 days.
Ambient temperature: 20°C
Setting: 6
1) Open the lubricator outlet by cutting off seal or removing plug.
Do not remove plug from oil filled units! Cut off the
protruding nipple with a knife; a small black point becomes
visible (opening now guaranteed).
2) To start the simalube lubricator, set the gas generator to the
required dispensing time (stepless in months, 1–12) using a
3 mm Allen key. The lubricator is activated once the dispensing
time has been set. Take the required dispensing quantity from
the tables on page 11.
3) Note the starting date on the label using a waterproof pen.
4) Clear grease lines and fill them with the appropriate grease.
Screw simalube onto the greasing point. If necessary, use acces-
sories shown on page 33–39. Apply safety rules.
5) Once the set dispensing time has expired, replace empty lubri-
cator with the same type or refill. Before restarting, clear grease
lines and fill them with the appropriate grease.
6) The gas generator is sufficient to empty the unit once,
irrespective of the dispensing time set.
Ambient temperature: 55°C
Setting: 7
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Simalube 60Simalube 125Simalube 250

Table des Matières