DMX OUT
6
Female three-pin XLR connector to transmit the DMX control signal.
LED DISPLAY
7
4-digit LED display for display of the DMX start address and other information.
CONTROL KEYS
8
MODE - press MODE to go to the processing menu and press MODE again to show the DMX start address on the display.
ENTER - press ENTER to go one level deeper in the processing menu and to confirm value or status changes.
UP / DOWN - use the UP and DOWN buttons to change a value, such as the DMX start address or the status of a menu item.
WINDOW
9
Window to monitor the canister fill level. The canister is illuminated to make fill level monitoring easier. In the heating phase red LEDs are
permanently on. Once the heating phase has been completed and the device is ready for use, blue LEDs light up.
12
the Adam Hall Group
pach · Germany
RMANY. Assembled in PRC
CANISTER
10
Fluid canister with screw cap and intake hose. The sinter filter on the end of the intake hose ensures that contaminant particles do not get
into the system and that the hose end is always at the lowest point of the canister. Completely disconnect the fog machine from the power
supply (remove the power plug) before filling the canister. Let the fog machine cool down sufficiently to prevent burn injuries. Unscrew the
lid of the canister and fill it with suitable fog fluid. Make sure that no fog fluid enters the device (take canister out of the fog machine). Put
the intake hose back into the canister and carefully close it using the lid. Never operate the fog machine without fog fluid.
FOG OUTPUT NOZZLE
11
The fog output nozzle is located on the front side of the fog machine. Caution, very hot! When setting up and installing the fog machine,
follow the information under "CAUTION! IMPORTANT INFORMATION ON FOG MACHINES!" in the safety instructions.
HANDLE SCREWS
12
Handle screws for adjustment of the mounting bracket.