Télécharger Imprimer la page

Exquisit EKI3050/2 Instructions D'utilisation Et D'installation page 34

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL CONNECTION
 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
 If the power cord is defective, it must be replaced by a power cord or an available
equivalent set from the manufacturer or from an approved repairer or retailer.
It is not necessary to add a power cord to the appliance; a power cord, with an E/F type
electrical plug, is already installed.
Caution!
This appliance must only be connected to a network 230 V~ 50/60 Hz.
Always connect the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover. Attach the earth to the terminal
"earth", the neutral N to terminal N, the Phase L1 to one of the terminals L.
Mains
Connection
230V~ 50/60Hz
1 Phase + N
Caution!
Ensure that the cables are correctly inserted and tightly screwed down.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.
Cable diameter
3 x 1.5 mm²
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Protection
Cable
calibre
H 05 VV - F
16 A *
H 05 RR - F
34
Diagram

Publicité

loading