Changing of parameters:
Press this key continuously for 5 seconds to access the list of parameters.
Display shows 'PS', press SET and use UP/Down keys to enter password '22'.
Press SET.
Press this key to scroll up through the parameter-list.
Press this key to scroll down through the parameter-list.
Press this key to select the parameter to change, the display will show the actual value, use
the up/down keys to change the value and confirm with 'Set':
Press the SET key continuously for 5 seconds to store the data.
See table of parameters from page 30.
Alarm codes:
EO
Flashing in the display: indicates that the cabinet sensor is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
HI
Flashing in the display: indicates that the temperature is too high.
LO
Flashing in the display: indicates that the temperature is too low.
Defrosting
We recommend defrosting the freezer every three month or if the layer of ice exceeds 5 mm.
Do never use metal or other sharp objects to scrape the internal sides as it can damage the freezer
1. Disconnect the freezer
2. Empty the freezer
3. Leave the freezer with the lid open
4. Use the plastic scraper to remove the ice from the inner liner
5. Remove the drain plug and open the drain on the back side of the freezer and place a tray
under the drain
6. Clean the freezer with mild detergent and wipe thoroughly
7. Connect the freezer and it is ready for use.