Télécharger Imprimer la page

BE BE3500IP Mode D'emploi page 9

Masquer les pouces Voir aussi pour BE3500IP:

Publicité

PREPARATION
5. PREPARATION
5.1 Fuel
DANGER
• Fuel is highly flammable and poisonous. Check
"SAFETY INFORMATION" carefully before filling.
• Do not overfill the fuel tank, otherwise it may
overflow when the fuel warms up and expands.
• After filling, make sure the fuel tank cap is
tightened securely.
NOTICE
• Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel
may deteriorate painted surfaces or plastic parts.
• Use only unleaded gasoline. The use of leaded gasoline will cause
severe damage to internal engine parts.
Remove the fuel tank cap and fill the fuel into the tank up to the red level.
(1) Red line
(2) Fuel level
Recommended fuel:
Unleaded gasoline
Fuel tank capacity:
Total: 4.0L (1.06 US gal, 0.88 lmp gal)
5.2 Engine oil
NOTICE
• Check oil levels before starting the engine. If empty, refill with
sufficient engine oil.
1. Place the generator on a level surface.
2. Turn the oil service knob to "OPEN" and remove the service door.
16
1. Place the generator on a level surface.
2. Screw the oil service door knob to "OPEN" and remove the oil service door.
3. Screw-out the oil plug, then screw-in sealing plug into the pouring orifice,
and use the funnel to add the specified amount of oil.
PREPARATION
4. Screw the oil plug, installed oil service door and keep the knob to "CLOSE".
Oil service door
Lubricating oil pipe
3. Unscrew the oil plug and then screw the sealing screw into the
Recommended engine oil: SAE SJ 15W-40
pouring orifice. Use the funnel to aid the specified amount of oil.
Recommended engine oil grade: API Service SE type or higher
4. Screw the oil plug back in, reinstall the oil service door, and turn the
Engine oil quantity: 0.6 L
knob to the "CLOSED" position.
Recommended engine oil: SAE SJ 15W-40
Recommended engine oil grade: API Service SE type or higher
Engine oil quantity: 0.5 L
5.3 Pre-Operation check
WARNING
- 16 -
• If any item in the Pre-operation check is not working properly, have it
inspected and repaired before operating the generator.
• The condition of a generator is the owner's responsibility. Vital
components can start to deteriorate quickly and unexpectedly, even if
the generator unused.
TIP: Pre-operation checks should be made each time the generator is
used.
Pre-operation check
Fuel (See page 16)
• Check fuel level in fuel tank.
• Refuel if necessary.
Engine oil (See page 17)
• Check oil level in engine.
• If necessary, add recommended oil to specified level.
• Check generator for oil leakage.
Oil plug
17

Publicité

loading

Produits Connexes pour BE BE3500IP

Ce manuel est également adapté pour:

Be3600ie