NOTICE
• Be sure the ESC is turned off while charging the battery.
• Be sure to connect the red battery charger lead to the positive (+)
battery terminal ,and connect the black lead to the negative (-) battery
terminal. Do not reverse these positions.
• Connect the battery charger leads to the battery terminals securely
so that they are not disconnected due to engine vibration or other
disturbances.
• Charge the battery in the correct procedure by following instructions
in the owner's manual for the battery.
• The DC protector turns off automatically if current above the rated
flows during battery charging. To restart charging the battery, turn the
DC protector on by pressing its button to "ON". If the DC protector
turns off again, top charge the battery immediately and consult our
company authorized dealer.
TIP:
• Follow instructions in the owner's manual for the battery to determine
the end of battery charging.
• Measure the specific gravity of electrolyte to determine if the battery is
fully charged. At full charge, the electrolyte specific gravity is between
1.26 and 1.28.
• It is advisable to check the specific gravity of the electrolyte at least
once every hour to prevent overcharging the battery.
WARNING
• Never smoke or make and break connections at the battery while
charging. Sparks may ignite the battery gas.
• Battery electrolyte is poisonous and dangerous, causing severe
burns, etc. contains sulfuric (sulphuric) acid. Avoid contact with skin,
eyes or clothing.
• Antidote:
EXTERNAL: Flush with water.
INTERNAL: Drink large quantities of water or milk. Follow with milk of
magnesia, beaten egg or vegetable oil . Call physician immediately.
EYES: Flush with water for 15 minutes and get prompt medical
attention.
• Batteries produce explosive gases. Keep sparks, flame, cigarettes,
etc., away. Ventilate when charging or using in closed space. Always
cover eyes when working near batteries.
• Keep out of reach of children.
22
OPERATION
6.5 Application range
When using the generator, make sure the total load is within rated output
of a generator. Otherwise, generator damage may occur.
AC
Power
1
0.8-0.95
Factor
3,000W
2,400W
Rated
output
power
TIP:
• Application wattage indicates when each device is used by itself.
• The simultaneous usage of AC and DC power is possible but total
wattage should not exceed the rated output.
EX:
Generator rated output
Frequency
Power factor
AC
1.0
DC
The overload indicator (1) comes on when total wattage exceeds the
application range. (See page 11 for more details.)
0.4-0.75
(Efficiency
0.85)
1,020W
Rated
voltage 12V
3,000W
3,000W
100W (12V/8.3A)
---
23