Télécharger Imprimer la page

BE BE3500IP Mode D'emploi page 10

Masquer les pouces Voir aussi pour BE3500IP:

Publicité

PREPARATION
6. OPERATION
WARNING
• Never operate the engine in a closed area or it may cause
unconsciousness and death within a short time. Operate the engine
in a well ventilated area.
• Before starting the engine, do not connect any electric devices.
NOTICE
• The generator has been shipped without engine oil. Do not start the
engine till fill with the sufficient engine oil.
• Do not tilt the generator when adding engine oil. This could result in
overfilling and damage to the engine.
TIP: The generator can be used with the rated output load at standard
atmospheric conditions.
"Standard atmospheric conditions"
Ambient temperature 25°
Barometric pressure 100kPa
Relative humidity 30%
The output of the generator varies due to change temperature, altitude
(lower air pressure at higher altitude) and humidity.
The output of the generator is reduced when the temperature, the
humidity and the altitude are higher than standard atmospheric
conditions.
Additionally, the load must be reduced when using in a confined area, as
generator cooling is affected.
18
(Recoil)
Turn the
switch knob
to "CHOKE" .
a. Ignition circuit is switched on.
OPERATION
b. Fuel is switched on.
c. chock is switched off
6.1 Starting the engine
TIP:
The choke is not required to start a
1. Turn the ESC switch to "OFF" (1).
knob in to the position "ON".
(Electric)
Turn the switch to "CHOKE" .
a. Ignition circuit is switched on.
b. Fuel is switched on.
c. Chock is switched off.
2. Turn the air vent knob to "ON" (2).
Press the electric start switch
d.
as shown in the figure.
3. Turn the 3 in 1 switch to
"CHOKE" (3),
a. Ignition circuit is switched on.
b. Fuel is switched on.
TIP:
The choke is not required to start a
c. Choke is switched on
knob in to the position "ON".
Press the electric start switch as shown
TIP: The choke is not required to start a warm engine. Push the choke
in the figure.
knob in to the position
"ON".
4. Pull slowly on the recoil starter until it is
4. Pull slowly on the recoil starter until
engaged, then pull it briskly.
it is engaged, then pull it briskly.
TIP: Grasp the carrying handle firmly to prevent
the generator from falling over when pulling the
recoil starter.
TIP: Grasp the carrying handle firmly to prevent the generator from falling
over when pulling the recoil starter.
- 19 -
5. After the engine starts, warm up the
engine until the engine does not stop
when the choke knob is returned to the
"ON" position (4).
TIP: When starting the engine, with the ESC "ON", and there is no load
on the generator:
• In ambient temperature below 0°C (32°F), the engine will run at the
rated r/min (4500r/min) for 5 minutes to warm up the engine.
• In ambient temperature below 5°C (41°F), the engine will run at the
rated r/min (4500r/min) for 3 minutes to warm up the engine.
• The ESC unit operates normally after the above time period, while the
ESC is "ON".
Recoil
warm engine. Push the choke
Press towards
the left
Electric
warm engine. Push the choke
Handle
19

Publicité

loading

Produits Connexes pour BE BE3500IP

Ce manuel est également adapté pour:

Be3600ie