THERMOSTAT
The thermostat and the light switch is placed in the bottom panel.
The thermostat has been pre-set and in most cases it is not necessary to adjust the settings.
When turning on the cabinet the display will show the current temperature in the cabinet.
Display set temperature:
Press this key and the display will show the set temperature. Press the key again to
return to normal reading
Set new temperature:
Press this key continuously for more than 3 seconds and the display shows the set
temperature.
Press this key to increase the set temperature.
Press this key to lower the set temperature.
Press this key to save the new settings. The display will flash with the new value and
will then return to normal reading.
Alarm codes:
'P1'
Flashing in the display: indicates that the cabinet sensor is defective.
The cabinet will strive to keep the set temperature until it has been repaired.
DEFROSTING
The cabinet defrosts automatically with pre-set intervals. If the door to the cabinet is opened or
the contents of the cabinet is changed frequently it may become necessary to defrost the cabinet
manually.
Pressing this key continuously for more than 3 seconds will start a manual defrosting
and then return to normal operation.
Defrosted water runs to a container placed in the compressor compartment and evaporates.