Bearing B
In addition, the fan is equipped with two ball bearings inside of the electric motor.
Switch and Cable WP
A fan that is equipped with a pull-down switch and cable shall be connoted to a power outlet. The fan is turned on
and off by pulling down the string that is located on the bottom of the fan.
Timer T
The fan is turned on by the S1 power switch (Drawing 4) or by turning on the light (Drawing 5). After turning off
the light or the switch, the fan continues its operation for a specific time interval that is set up by a controller. This
interval may be 1 to 30 minutes long.
Caution! The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.
Humidity Sensor HT
The fan is equipped with a humidity level control that may be used to set the level of humidity from ~60%RH -
~90%RH and a delay control that may be used to set the delay from 1 to 30 min. The fan is turned on automatically
when a certain humidity level is reached in the room or it may be turned on manually by a switch. Connection
diagram is shown in Drawing 4-5. The fan is turned off after a pre-set time interval. Humidity "H" and delay
"T" controllers are located on the control unit (Drawing 7). To set the maximum humidity level (~ 90% RH) for
moisture regulator "H" need turned fully clockwise.
Caution! The fan power switch S1 (Drawing 4, drawing 5) must not be equipped with an LED light indicator.
Timer, Cable, and Switch TWP
A fan that is equipped with a timer, cable, and switch is turned on by a pull-down switch. It will turn off after the
pre-set time interval. To adjust the timer, see section "Timer T".
Humidity Sensor, Timer, Cable, and Switch HTWP
A fan that is equipped with a humidity sensor, cable, and switch is turned on by a pull-down switch or after a
certain humidity level is reached in the room. It turns on after the pre-set time interval or if humidity in the room
drops to a certain level. To adjust the humidity sensor, see section "Humidity Sensor HT".
12V motor - 12
The fan is equipped with a 12V motor. A fan intended to be installed together with 12V power supply.
Caution! Fans with electronic control unit must be adjusted before they are connected to the power
network.
Caution! If the potentiometer is set to "1 min", the fan will turn on for a couple of seconds after
connected it to the power network.
Guarantee
Producer guarantee is 24 months.
In the case of damages contact the place of trade.
The guarantee does not cover:
1. noted mechanical or other damages
2. mechanical or other damages caused by incorrect or improper usage, misuse, abuse or neglect
3. mechanical or other damages caused by incorrect installation or by product's incorrect fitting to insufficient
or unsuitable power
4. mechanical or other damages caused by ignoring the instruction manual conditions
A guarantee does not cover natural wear of the product.
Utilization
Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical
and electronic equipment should not be disposed of as general household waste at its end-oflife.
Instead, the products should be handed over to the appliance collection points for the recycling
of electrical and electronic equipment, recovery and recycling in accordance with your national
legislation and the Directive 2002/96/EC and 2006/66/EC.
45
EN

Publicité

loading

Ce manuel est également adapté pour:

Eextra eet100Eextra eet125Eextra eet150