1. If bracket is to be mounted to wood floor, use a drill with a 1/8" drill bit to drill
the four holes.
If bracket is to be mounted to cement or ceramic floor, use a drill with a 3/16"
drill bit to drill the four holes.
ANTI-TIP BRACKET PLACEMENT
Dim.
A
B
Option 1
Option 2
(Using the short
(Using the long
2 screws.)
2 screws.)
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 27
DG68-01554A-00_IM_DOP48T960DS, DOP48T963DS_DA_EN+MES+CFR.indb 27
Range center line
TOP
VIEW
B
Range
front panel
C
A
DOP48*96*D*
6 1/4" (15.9 cm)
23 7/8" (60.7 cm)
2. Line up the holes on anti-tip
bracket with the holes in
floor or the Wall plate as
shown in Options 1 and 2.
Secure the bracket in place
with a Phillips Screwdriver
and using two of the four
screws provided.
*approximately
21/32" (16.5 mm)
Screw must enter
wood or concrete.
3. Level range by adjusting the leveling legs with a wrench.
Use a spirit level to check your adjustments. Plug the power supply cord into
the grounded outlet. Slide range back into position. To check visually that rear
leveling leg is inserted into bracket, grasp the top rear edge of the range and
carefully attempt to tilt it forward.
Leveling leg
NOTE
To install the Anti-tip bracket, release the leveling leg using pipe wrench because
Loctite is applied on Bolt for vibration unlocking. A minimum clearance of 1
(35.1 mm) is required between the range bottom and the kitchen floor.
To check if the bracket is installed and engaged properly, remove the kick panel
and look underneath the range to see that the leveling leg is engaged in the
bracket. Carefully tip the range forward. The bracket should stop the range within
4 inches (10.2 cm) of tipping. If it does not, the bracket must be reinstalled.
If the range is pulled from the wall for any reason, always repeat this procedure to
verify the range is properly secured by the anti-tip bracket. Never completely remove
the leveling legs or the range will not be secured to the anti-tip device properly.
Anti-Tip
bracket
Wall sill
plate
Screw must
enter wood.
Leveling
leg
Anti-Tip bracket
/
"
3
8
English 27