Device Installation (UK)
Note:
Prior to installation, ensure that all devices that will be connected to this system are powered off.
Ensure that all devices that will be connected are properly earthed.
Place cables away from fluorescent lights, air conditioners and machines that are likely to generate electrical noise.
Allow adequate space around the unit for air circulation.
Earthing: To prevent any damage to the product or any connected devices, and to improve audio/video signal quality, it is important to ensure that the
extender systems are properly earthed.
Transmitter unit
Step 1. Use an HDMI cable to connect the source device to the port labelled HDMI IN on the transmitter unit.
Step 2. Use the supplied mini-USB to USB-A cable to connect the mini-USB port on the transmitter unit and the USB-A port of the source device.
Step 3. Use a 3.5 mm audio cable to connect the port labelled STEREO IN on the transmitter and the 3.5 mm audio output port of a source device (if needed).
Step 4. Use a TOSLINK cable to connect the port labelled TOSLINK IN on the transmitter and the TOSLINK output port of a source device (if needed).
Step 5. Connect a supplied RJ11 to DB9 adaptor to a supplied RJ11 serial extension cable, connect the RJ11 connector of the RJ11 serial extension cable to the
port labelled RS232 on the transmitter, and connect the DB9 connector of the RJ11 to DB9 adaptor to a DCE (if needed).
Step 6. If choosing to connect the supplied IR receiver to the port labelled IR IN on the transmitter unit, please connect the supplied IR transceiver to the port
labelled IR OUT on the receiver unit. Otherwise, connect the supplied IR transceiver to the port labelled IR OUT on the transmitter unit, then connect the
supplied IR receiver to the port labelled IR IN on the receiver unit.
Step 7. Use a CAT5e/6/7 cable to connect to the RJ45 port on the transmitter and receiver. For a better EMI compliance, it's suggested to use ferrite cores to
the following places:
a.) Attach ferrite cores to both ends of the CAT cable, one for each, where the ferrite core is close to the Tx and Rx units.
b.) Attach a ferrite core to the HDMI cable in between Tx and PC, where the ferrite core is close to the Tx unit.
c.) Attach a ferrite core to HDMI cable in between Rx and monitor, where the ferrite core is close to the Rx unit.
Receiver unit
Step 1. Connect an HDMI display to the port labelled HDMI OUT on the receiver unit using an HDMI cable.
Step 2. Connect all peripheral USB devices to the USB-A port on the receiver unit (if needed).
Step3. Use a 3.5 mm audio cable to connect the port labelled STEREO OUT on the receiver and the 3.5 mm audio input port of a display or speaker (if needed).
Step 4. Use a TOSLINK cable to connect the port labelled TOSLINK OUT on the receiver and the TOSLINK input port of a display or a TOSLINK source device (if
needed).
Step 5. Connect a supplied RJ11 to DB9 adapter to a supplied RJ11 serial extension cable, connect the RJ11 connector of the RJ11 serial extension cable to the
port labelled RS232 on the receiver, and connect the DB9 connector of the RJ11 to DB9 adapter to a DTE (if needed).
Step 6. Once all the devices are connected, attach the supplied power adaptor to the transmitter unit.