Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

NUR ORIGINAL MIT DER RAUTE
WITA go.future LED 40-XX | 60-XX
EEI
≤ 0,20
ORIGINAL EINBAU- UND
D
BETRIEBSANLEITUNG
SEITE 2–17
TRANSLATION OF THE ORIGINAL INSTALLATION
GB
AND OPERATING INSTRUCTIONS
PAGE 18–33
TRADUCTION DES INSTRUCTIONS DE MONTAGE
FR
ET DE SERVICE ORIGINALES
PAGE 34–49
|
|
www.wita.de

Publicité

loading

Sommaire des Matières pour WITA LED 40 Serie

  • Page 1 NUR ORIGINAL MIT DER RAUTE WITA go.future LED 40-XX | 60-XX ≤ 0,20 ORIGINAL EINBAU- UND BETRIEBSANLEITUNG SEITE 2–17 TRANSLATION OF THE ORIGINAL INSTALLATION AND OPERATING INSTRUCTIONS PAGE 18–33 TRADUCTION DES INSTRUCTIONS DE MONTAGE ET DE SERVICE ORIGINALES PAGE 34–49...
  • Page 2 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Inhalt Konformitätserklärung ..........................3 Sicherheitshinweise ............................. 4 2.1 Allgemeines ..............................4 2.2 Kennzeichnung von Hinweisen in der Betriebsanleitung ..............4 2.3 Personalqualifikation ........................... 5 2.4 Gefahren bei Nichtbeachtung der Sicherheitshinweise ..............6 2.5 Sicherheitsbewusstes Arbeiten ........................ 6 2.6 Sicherheitshinweise für den Betreiber ....................
  • Page 3 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX EU Konformitätserklärung Name des Ausstellers: WITA-Wilhelm Taake GmbH Display HE Pumpen Pumpen-, Armaturen- und Regeltechnik Böllingshöfen 85 D-32549 Bad Oeynhausen Gegenstand der Erklärung: Heizungs-Umwälzpumpe Typ: go.future LED Ausführung: 40-XX, 60-XX Wir erklären in alleiniger Verantwortung, dass die oben genannten Produkte, auf die sich diese EU-Konformitätserklärung bezieht, mit den folgenden Normen und...
  • Page 4 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX 2 Sicherheitshinweise 2.1 Allgemeines Diese Einbau- und Betriebsanleitung ist Bestandteil des Produktes und enthält grundlegende Informationen, die bei Montage, Betrieb und Wartung zu beachten sind. Aus diesem Grund muss sie unbedingt vor der Aufstellung vom Monteur und dem zuständigen Fachpersonal bzw.
  • Page 5 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Hier stehen nützliche Hinweise zur Hinweis Handhabung des Produktes. Sie machen auf mögliche Schwierigkeiten aufmerk- sam und sollen für einen sicheren Be- trieb sorgen. Direkt am Produkt angebrachte Hinweise wie zum Beispiel: • Drehrichtungspfeil •...
  • Page 6 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX 2.4 Gefahren bei Nichtbeachtung der Sicherheitshinweise Werden die Sicherheitshinweise nicht beachtet, kann dies eine Gefährdung von Personen, Umwelt und Anlage zur Folge haben. Die Nichtbeachtung der Sicherheitshinweise führt zum Verlust jeglicher Schadenersatzansprüche. Mögliche Gefährdungen sind zum Beispiel: •...
  • Page 7 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX • Gefährdungen durch elektrische Energie müssen ausgeschlossen werden. Hierzu sind z. B. die Vorschriften des VDE und der lokalen Energieversorgungsunternehmen zu beachten. Display HE Pumpen • Sollten an der Anlage Gefahren durch heiße oder kalte Teile auftreten, so müssen diese mit einem Berührungsschutz...
  • Page 8 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX zugelassenes Zubehör verwendet werden. Werden andere Teile verwendet, so ist eine Haftung des Herstellers für die daraus entstehenden Folgen ausgeschlossen. 2.9 Unzulässige Betriebsweisen Wird die Pumpe vom Netz getrennt, muss vor Wiedereinschal- ten eine Wartezeit von mindestens 1 Minute eingehalten werden.
  • Page 9 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX 4 Bestimmungsgemäße Verwendung Die WITA Hocheffizienzpumpen go.future LED 40-XX | 60-XX sind für das Umwälzen von Warmwasser in Zentralheizungen konzipiert und eignen sich auch Display HE Pumpen zur Förderung dünnflüssiger Medien im Bereich Industrie und Gewerbe. Sie sind auch für solartechnische Anlagen geeignet.
  • Page 10 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Technische Daten go.future LED 60-XX Kennlinie WITA go.future LED 60 4 Qm Maximale Förderhöhe 6,0 m Maximaler Durchfluss 3.200 l/h Leistungsaufnahme P1 (W) 3 - 38 Versorgungsspannung 1 x 230V 50Hz Emissions-Schalldruckpegel < 40 dB(A) ≤...
  • Page 11 Energieeffizienzindex von ≤ 0,20 aufweist. Durch den Einsatz der Display HE Pumpen WITA go.future LED kann der Energieverbrauch gegenüber einer herkömmlichen Umwälzpumpe bis ca. 80% gesenkt werden. Die hydraulische Leistung konnte gegenüber den Standardpumpen nahezu gleichgehalten werden.
  • Page 12 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Display Das Display leuchtet, sobald die Pumpe an die Versorgungsspannung ange- schlossen wird. Es wird die aktuelle Leistungsaufnahme während des Betriebs angezeigt. Störungen werden im Display als Fehler „E1“, „E2“ oder „E3“ angezeigt. Die angezeigten Fehler sind vom Betreiber nicht zu beheben und nur als Hinweis für den...
  • Page 13 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX 8 Pumpeneinstellung Regelungsarten Display HE Pumpen Proportionaldruckregelung Während des Betriebes erfolgt die Regelung der Pumpe nach der Proportionaldruckregelung. Hierbei wird der Differenzdruck über der Pumpe in Abhängigkeit vom Förderstrom geregelt. Die Proportionaldruck-Kennlinien sind in den jeweiligen Q/H Diagrammen mit PD1 bis PD4 ge- kennzeichnet.
  • Page 14 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Permanente Nachtabsenkung Die Nachtabsenkung lässt sich permanent einschalten. Nach Aktivierung der Nachtabsenkung muss die Taste erneut für 5 Sekunden gedrückt werden. Nach Loslassen der Taste erscheint „-C“ im Display. Die Pumpe bleibt dauerhaft im abgesenkten Betrieb bis •...
  • Page 15 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX Display HE Pumpen Fig. 2a Fig. 2b Fig. 2c Fig. 2d 10 Elektrischer Anschluss Achtung Lebensgefahr! Unsachgemäße Installation und unsachgemäßer elektrischer Anschluss können lebensgefähr- lich sein. Gefährdungen durch elektrische Energie sind auszuschließen. • Installation und elektrischen Anschluss nur durch Fachpersonal und gemäß der geltenden Vorschriften (z.
  • Page 16 Bedienungsanleitung WITA go.future LED 40-XX | 60-XX 10.1 Montage des Netzsteckers Click Click Schließen Sie das Netzkabel wie dargestellt an die Pumpe an. Vorsicht Netzspannung! Unbe- dingt die erforderlichen Schutz-Maßnahmen, VDE-Vorschriften und örtlichen Bestimmungen beachten. Der Leiterquerschnitt darf nicht kleiner als 0,75 mm2 sein. Bei Verwendung von feindrähtigen Leitungen sind Aderendhülsen zu benutzen.
  • Page 17 WITA go.future LED 40-XX | 60-XX 12 Wartung/Service Vor Wartungs-, Reinigungs- und Reparaturarbeiten Anlage spannungsfrei schalten und gegen unbefugtes Wiedereinschalten sichern. Display HE Pumpen Bei hohen Wassertemperaturen und Systemdrücken Pumpe vorher abkühlen lassen. Es besteht Verbrühungsgefahr! 13 Störungen, Ursachen und Beseitigungen 1.
  • Page 18 Operating Instrutions WITA go.future LED 40-XX | 60-XX Contents Declaration of conformity ........................19 Safety Instructions ............................ 20 2.1 General ................................20 2.2 Identification of notes in the operating instructions ................ 20 2.3 Personnel qualification ..........................21 2.4 Danger of not observing savety instructions ..................22 2.5 Safety-conscious working ........................
  • Page 19 Operating Instrutions WITA go.future LED 40-XX | 60-XX EC Declaration of Conformity Name of the issuer: WITA-Wilhelm Taake GmbH Display HE Pumpen Pump, valve and control technology Böllingshöfen 85 D-32549 Bad Oeynhausen Subject of the declaration: Heat circulation pump Type: go.future LED...
  • Page 20 Operating Instrutions WITA go.future LED 40-XX | 60-XX 2 Safety Instructions 2.1 General These installation and operating instructions are a part of the product, and contain basic information that must be observed during installation, operation and maintenance. For this reason, the installer and specialist personnel or operators must read these instructions prior to set-up.
  • Page 21 Operating Instrutions WITA go.future LED 40-XX | 60-XX This symbol indicates useful information Note for handling the product. It indicates potential difficulties and aims to ensure safe operation. Signs attached directly on the product, such as: • direction of rotation arrow •...
  • Page 22 Operating Instrutions WITA go.future LED 40-XX | 60-XX 2.4 Danger of not observing safety instructions Not observing the safety information can endanger persons, the environment and the system. Not observing the safety instructions shall result in the loss of any and all claims to warranty.
  • Page 23 Operating Instrutions WITA go.future LED 40-XX | 60-XX • Observe the instructions in local or general regulations (e.g. IEC, VDE, etc.), and those of the local energy supplier. • In the event of hazards arising from the system due to Display HE Pumpen contact with hot or cold parts, these parts must be fitted...
  • Page 24 Operating Instrutions WITA go.future LED 40-XX | 60-XX bear no liability for any consequences resulting from the use of other parts. 2.9 Unpermitted operation If the pump is disconnected from the power supply, wait at least 1 minute before reactivating. Otherwise, the pump's inrush current limit has no effect, which can lead to functional errors or damage to any connected heating controller.
  • Page 25 WITA go.future LED 40-XX | 60-XX 4 Intended Use The WITA go.future LED 40-XX / 60-XX high-efficiency pumps are designed for circula- ting hot water in central heating systems, and are also suitable for conveying thin liquid Display HE Pumpen media in indudustrie and commerce.
  • Page 26 Operating Instrutions WITA go.future LED 40-XX | 60-XX Technical data go.future LED 60-XX Characteristics WITA go.future LED 60 4 Qm Max. pump lift 6.0 m Max. flow rate 3.200 l/h Power consumption P1 (W) 3 - 38 Supply voltage 1 x 230V 50Hz Emission sound pressure level <...
  • Page 27 Operating Instrutions WITA go.future LED 40-XX | 60-XX 6 Description of the Pumps In an average household, around 10 to 20% of the energy consumption is caused by common standard pumps. With the go.future LED series of pumps, we have developed a circulation pump with an energy efficiency index of ≤...
  • Page 28 Operating Instrutions WITA go.future LED 40-XX | 60-XX Display The display lights up as soon as the pump is connected to the power supply. The current power consumption during operation is displayed. Faults are shown in the display as error “E1”, “E2” or “E3”. The displayed errors are not to be corrected by the owner/operator and are only provided as information for the customer service.
  • Page 29 Operating Instrutions WITA go.future LED 40-XX | 60-XX 8 Pump Settings Control types Display HE Pumpen Proportional pressure control During operation the pump is controlled by the proportional pressure control function. The differential pressure is controlled via the pump depending on the delivery rate. The proportional pressure characteristics are marked in the respective Q/H diagrams as PD1 to PD4.
  • Page 30 Operating Instrutions WITA go.future LED 40-XX | 60-XX Permanent night economy The night economy function can be switched on permanently. After activating the night economy function the button must be pressed again for 5 seconds. After releasing the button “- C” appears in the display.
  • Page 31 Operating Instrutions WITA go.future LED 40-XX | 60-XX Display HE Pumpen Fig. 2a Fig. 2b Fig. 2c Fig. 2d 10 Electrical connection Warning: Risk of death! Improper installation and improper electrical connection can present a fatal hazard. Hazards posed by electrical power must be eliminated.
  • Page 32 Operating Instrutions WITA go.future LED 40-XX | 60-XX 10.1 Assembling the power plug Click Click Connect the power cable to the pump as shown. Caution: Line voltage! Observe the required protective measures, national body regulations and local provisions at all times. The cable cross-section may be no smaller than 0.75 mm2.
  • Page 33 Dispose of the pump and/or parts in an environmentally conscious way. To do this, please contact a public or private disposal organisation. A list of the materials used in our products is provided in the download area of our website. (www.wita.de)
  • Page 34 Instructions de montage WITA go.future LED 40-XX | 60-XX Table des matières Déclaration de conformité ........................35 Consignes de sécurité ..........................36 2.1 Généralités ..............................36 2.2 Marquage des avertissements dans les instructions de service ........... 36 2.3 Qualification du personnel ...………………………………………… ..............37 2.4 Risques en cas de non-respect des consignes de sécurité...
  • Page 35 Instructions de montage WITA go.future LED 40-XX | 60-XX DÉCLARATION DE CONFORMITÉ EUROPÉENNE Nom du déclarant : WITA-Wilhelm Taake GmbH Display HE Pumpen Pompes, armatures et technique de réglage Böllingshöfen 85 D-32549 Bad Oeynhausen Objet de la déclaration: circulateur de chauffage Type: go.future LED...
  • Page 36 Instructions de montage WITA go.future LED 40-XX | 60-XX 2 Consignes de sécurité 2.1 Généralités Les présentes instructions de montage et de service font partie intégrante du produit et contiennent des informations importantes à respecter lors du montage, de l'utilisation et de la maintenance.
  • Page 37 Instructions de montage WITA go.future LED 40-XX | 60-XX Ici, vous trouverez des informations Information utiles sur la manipulation du produit. Elles attirent l'attention sur d'éventuelles difficultés et assurent un fonctionnement sûr. Les marquages directement apposés sur le produit, tels que : •...
  • Page 38 Instructions de montage WITA go.future LED 40-XX | 60-XX 2.4 Risques en cas de non-respect des consignes de sécurité Le non-respect des consignes de sécurité peut entraîner des dangers pour les personnes, l'environnement et l'installation. Le non-respect des consignes de sécurité donne lieu à la perte de tout droit d'indemnisation.
  • Page 39 Instructions de montage WITA go.future LED 40-XX | 60-XX • Tout risque dû à l'énergie électrique doit être exclu. Pour cela, les prescriptions VDE, par exemple, et les directives des compagnies d'électricité locales doivent être respectées. En cas de risque émanant des pièces Display HE Pumpen chaudes ou froides de l'installation, celles-ci doivent être...
  • Page 40 Instructions de montage WITA go.future LED 40-XX | 60-XX exclusivement des pièces originales. Utiliser exclusivement les accessoires homologués par le fabricant. Le fabricant ne peut pas être tenu responsable des dommages résultant de l'utilisation de pièces autres que celle prescrites.
  • Page 41 Instructions de montage WITA go.future LED 40-XX | 60-XX 4 Utilisation according to specification Les pompes extrêmement efficaces WITA go.future LED 40-XX / 60-XX ont été conçues pour faire circuler l'eau chaude dans les chauffages centraux, mais elles Display HE Pumpen s'utilisent également pour le refoulement de fluides très liquides dans le domaine...
  • Page 42 Instructions de montage WITA go.future LED 40-XX | 60-XX Caractéristiques techniques go.future LED 60-XX Courbe caractéristique WITA go.future LED 60-XX 4 Qm Hauteur de refoulement maximale 6,0 m Débit maximal 3.200 l/h Puissance consommée PI (W) 3 - 38 Tension d'alimentation 1 x 230V 50Hz Niveau de pression acoustique des émissions...
  • Page 43 Instructions de montage WITA go.future LED 40-XX | 60-XX 6 Description de la pompe Dans un ménage moyen, 10 à 20 % du courant consommé sont utilisés par des pompes standard classiques. Avec la série de pompes go.future LED nous avons conçu une pompe de circulation présentant un indice d'efficacité...
  • Page 44 Instructions de montage WITA go.future LED 40-XX | 60-XX Écran L’écran s’allume dès que la pompe est raccordée à la tension d’alimentation. La puissance absorbée actuelle est affichée pendant le fonctionnement. Les défauts sont indiqués à l’écran en tant qu’erreur « E1 », « E2 » ou « E3 ».
  • Page 45 Instructions de montage WITA go.future LED 40-XX | 60-XX 8 Réglage de la pompe Types de réglage Display HE Pumpen Réglage de la pression proportionnelle Le réglage de la pompe s’effectue pendant le fonctionnement, après le réglage de la pression proportionnelle.
  • Page 46 Instructions de montage WITA go.future LED 40-XX | 60-XX Abaissement nocturne permanent L’abaissement nocturne peut être activé en permanence. Après l’activation de l’abaissement nocturne, appuyer à nouveau sur pendant 5 secondes. Après avoir relâché le bouton, l’écran affiche « -C ». La pompe reste durablement en fonctionnement abaissé jusqu’à...
  • Page 47 Instructions de montage WITA go.future LED 40-XX | 60-XX Display HE Pumpen Fig. 2a Fig. 2b Fig. 2c Fig. 2d 10 Raccordement électrique Attention – danger de mort ! Une installation et une connexion électrique non conformes peuvent être mortelles. Toute mise en péril par de l'énergie électrique doit être exclue.
  • Page 48 Instructions de montage WITA go.future LED 40-XX | 60-XX 10.1 Montage de la fiche Click Click Brancher le câble d'alimentation à la pompe comme illustré. Attention, système sous tension ! Respecter impérativement les mesures de protection nécessaires, les directives VDE et les directives locales.
  • Page 49 WITA go.future LED 40-XX | 60-XX 12 Maintenance et entretien Mettre l'installation hors tension avant de procéder aux travaux d'entretien, de nettoyage et de réparation et la protéger contre une remise en marche non Display HE Pumpen autorisée. Si l'eau est très chaude et si les pressions du système sont élevées, laisser d'abord refroidir la pompe.
  • Page 50 Notes...
  • Page 51 Notes Display HE Pumpen...
  • Page 52 NUR ORIGINAL MIT DER RAUTE WITA - Wilhelm Taake GmbH HEL-WITA Sp. z o.o. Böllingshöfen 85 | D-32549 Bad Oeynhausen Zielonka, ul. Biznesowa 22 | 86-005 Białe Błota Tel.: +49 5734 512380 | Fax: +49 5734 1752 Tel.: + 52 564 09 00 | Fax: + 52 564 09 22 www.wita.de | info@wita-taake.de...

Ce manuel est également adapté pour:

Led 60 serie