Finished
1/2"
Wall
(1.3 cm)
5-9/16" D.
(14.1 cm)
Plaster Guard
2-1/4" to 3"
Dome
(5.7 to 7.6 cm)
Rough-In Depth
2. Complete the Finished Wall
CAUTION: Risk of product damage. This valve contains plastic
and rubber components that may become damaged if soldering
heat is applied directly to the valve body.
CAUTION: Risk of damage to the K-306-KS valve assembly.
When using the K-306-KS HiFlow Valve in a fiberglass or acrylic
installation, use the Thin Wall Installation Kit (88526).
NOTE: Thick wall installations are typically tile, plaster, marble, or
similar materials. Thin wall installations are typically fiberglass and
acrylic.
NOTE: Do not adjust the maximum water temperature at this time.
Thick Wall Installation
Provide a 5-9/16" (14.1 cm) diameter hole in the wall material.
The flat front surface of the plaster guard must be flush with the
finished wall.
Complete the finished wall.
Kohler Co.
All manuals and user guides at all-guides.com
Attachment Hole
Backing Plate
Plaster Guard
Outer Ring
Valve Stem
Dome
Finished
Wall
Backing Plate
4" D. (10.2 cm)
Plaster
Guard
2-1/4" (5.7 cm)
Rough-In Depth