Copper Tube
Nut
Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Unthread the plastic nuts from the hot and cold inlets.
Remove the copper tubes. The O-ring and screen may be attached to the end of the tube.
If the screen remains in the check valve, use a small bladed screwdriver to gently pull the check
valve from the valve inlet.
Remove the screens from the copper tubes or check valves.
Clean the screens to remove any dirt or debris.
Rinse or replace the check valves and screens.
Reassemble the inlet connections.
9. Troubleshooting
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining
any residual water.
WARNING: Risk of electric shock. Disconnect power before servicing.
NOTE: For service parts information, visit your product page at www.kohler.com.
It is recommended that any valve maintenance be performed by a KOHLER Authorized Service
Representative.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4KOHLER.
Troubleshooting Table
Symptoms
1. Control panel is not lit.
Kohler Co.
All manuals and user guides at all-guides.com
Check Valve
O-Ring
Seal
Probable Cause
A. Valve is not plugged into the
outlet.
Screen
Recommended Action
A. Plug the valve into an outlet.