STEP 3 Connect the electrical wiring
First, read through the "Electrical requirements" section, and then follow these steps.
3-wire system
A
B
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E. ¾" (1.9 cm) UL-listed strain relief
DV8700K-03170T-00_EN (US)_151130.indd 19
All manuals and user guides at all-guides.com
1. Loosen or remove the center terminal
D
2. Connect the neutral wire (white or
C
3. Connect the other wires to outer
4. Tighten the strain relief screws.
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system
• Ring-type terminals are recommended.
block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
English 19
2015-11-30
12:26:44