Gas requirements
WARNING
• Use only natural or LP (liquid propane)
gases.
• THE INSTALLATION MUST CONFORM
WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH
THE NATIONAL FUEL GAS CODE ANSI/
Z223.1, LATEST REVISION (FOR THE
UNITED STATES), OR WITH THE CAN /
CGA-B149 INSTALLATION CODES (FOR
CANADA).
• Gas dryers are equipped with a burner
vent for use with natural gas. If you
plan to use your dryer with LP (liquid
propane) gas, it must be converted
for safe and proper performance by a
qualified service technician.
• A 1/2" (1.27 cm) gas supply line is
recommended and must be reduced to
connect to the 3/8" (1 cm) gas line on
your dryer. The National Fuel Gas Code
requires that an accessible, approved
manual gas shut-off valve be installed
within 6" of your dryer.
• Gas dryers installed in residential
garages must be raised 18 inches (46
cm) above the floor.
• Additionally, a 1/8" (0.3 cm) N.P.T.
(National Pipe Thread) plugged tapping,
accessible for test gauge connection,
must be installed immediately upstream
of your dryer's gas supply connection.
• Your dryer must be disconnected from
the gas supply pipe system during any
pressure testing of the system.
DV8700K-03170T-00_EN (US)_151130.indd 13
All manuals and user guides at all-guides.com
• Do not reuse old flexible metal gas
• Your dryer uses an automatic ignition
• Any pipe joint compound used must be
• As a courtesy, most local gas utilities
Commonwealth of Massachusetts
installation instructions
Your dryer must be installed by a licensed
plumber or gas fitter. A "T" handle manual
gas valve must be installed in the gas
supply line to your dryer. If a flexible gas
connector is used to install your dryer, the
connector can be no longer than 3' (36").
• Gas leaks may occur in your system,
• Gas leaks may not be detected by smell
• Gas suppliers recommend you purchase
• Install and use in accordance with the
lines. Flexible gas lines must be
design certified by the American Gas
Association (CGA in Canada).
NOTE
system to ignite the burner. There is no
constant burning pilot.
resistant to the action of any liquefied
petroleum gas.
will inspect a gas appliance installation.
WARNING
creating a dangerous situation.
alone.
and install a UL-approved gas detector.
manufacturer's instructions.
English 13