Charging station
B+
A-
GND
RS-485
Energy meter
36 / 68
External control device
External control
(dry contact)
NC
LERAK131B_20221004
Connect a dry contact module for override mode to the ter-
minals 4 and 5. Remove the jumper from the pre-installed
connector.
Note! If you do not connect a dry contact module to the charg-
ing station, do not remove the jumper or change the related
settings in the Charger Control application.
The default setting for external control is NC (normally
closed).
When the contact is closed, charging is allowed.
When the contact is opened, charging is not allowed.
If you install the external control as NO (normally open),
change the settings accordingly in the Charger Control ap-
plication.
External control
Normally closed
(NC)
Normally open
(NO)
Switch
Charging
Allowed
Not allowed
Allowed
Not allowed