LEAD-ACID
1
NORMAL
15.8V
RECOND
15.8V
Time limit:
STEP 1 DESULPHATION
Detects sulphated batteries. Pulsing current and voltage, removes
sulphate from the lead plates of the battery restoring the battery
capacity.
STEP 2 SOFT START
Tests if the battery can accept charge. This step prevents that
charging proceeds with a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 80% battery
capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery
capacity.
10 • EN
All manuals and user guides at all-guides.com
2
3
Increasing voltage to
Max 25A until 12.6V
14.4V, max 25A
Increasing voltage to
Max 25A until 12.6V
14.4V, max 25A
8h
20h
4
5
Declining current
Checks if voltage
14.4V
drops to 12V
Declining current
Checks if voltage
14.4V
drops to 12V
16h
3 minutes
STEP 5 ANALYZE
Tests if the battery can hold charge. Batteries that can not hold
charge may need to be replaced.
STEP 6 RECOND
Choose the Recond program to add the Recond step to the
charging process. During the Recond step voltage increases to
create controlled gassing in the battery. Gassing mixes the battery
acid and gives back energy to the battery.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a
constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger
monitors the battery voltage and gives a pulse when necessary to
keep the battery fully charged.
6
7
12.9V–14.4V
13.0V*, 13.6V
max 25A
Max 15.8V
12.9V–14.4V
13.0V*, 13.6V
Max 1.5A
max 25A
Charge cycle
10 days (*first day)
restarts if voltage
2h or 6h
charge cycle restarts
drops or 24h time
if voltage drops
8
20–1.2A
20–1.2A
passed