6 Target Group
The mechanical and electrical installation and setup of the device must be performed by a qualified tech-
nician who has demonstrated skill and knowledge related to the construction and operation of automotive
equipment and installations, and who is familiar with the applicable regulations of the country in which the
equipment is to be installed and/or used, and has received safety training to identify and avoid the haz-
ards involved.
7 Configuration
NOTICE! Damage hazard
Use a small screwdriver to carefully move the DIP switches to the required position.
1.
Setting up the alternator type:
Table 1: Alternator configuration
DIP switch position (gray)
2. Setting the charging program:
NOTICE! Damage hazard
Only use batteries that are suitable for the specified charging voltage.
Table 2: Charging curve configuration
DIP switch
position (gray)
8
Function
Standard alternator
Smart alternator
Function
Charging
Max. voltage (U
program
12 V
14.2 V
Lead gel bat-
teries
activated
deactivated
activated
deactivated
)
Float voltage (U
abs
24 V
12 V
28.4 V
13.5 V
13.3 V
12.7 V
11.7 V
11.25 V
)
Max. desulfation voltage
float
24 V
12 V
27 V
OFF
 
24 V