Télécharger Imprimer la page

NuTone ENTRY AD-500 Guide D'utilisation page 2

Masquer les pouces Voir aussi pour ENTRY AD-500:

Publicité

Les langues disponibles

Les langues disponibles

Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Database Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
System Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Setting up Multiple Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Programming Over the Telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Programming from the Local Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Programming Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Programming Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Resident Data Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Entry Code Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
System Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10
System Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11
AD-500 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12
NuTone Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Introduction
The Model AD-500 Telephone Entry & Access Control System
is designed for use as a primary access control device for gated
communities, parking garages, office buildings, apartment, dormitories,
hotels/motels, commercial buildings and recreational facilities with up to
250 residents or users.
Housed in a locked, rugged stainless steel faced enclosure, the AD-500
features a side-lit 12-key telephone style keypad with bright, easy-to-
read graphics, a backlit two-line directory display with programmable
welcome message, a built-in microphone, and speaker.
The two relay output channels can be programmed to control electric
door strikes, magnetic locks, door & gate operators, or barrier gates.
The system utilizes hands-free, full duplex telephone communications
between visitors and residents for granting access.
The system can be programmed locally using the keypad, remotely with
a touch tone telephone, or remotely using a computer equipped with a
modem and a web browser.
Before starting the installation, read and understand these instructions.
Become familiar with the illustrations and wiring diagrams. They will be
a guide to installing the system in an efficient and professional manner.
Operation
In a typical installation, the unit's memory would be programmed with
each resident's name and directory code number. Arriving visitors would
use the keypad on AD-500 to view the directory names and directory
number for the desired resident. Upon entering the directory number,
the AD-500 will automatically dial the resident's telephone number and
establish two-way voice communication between the visitor and the
resident. The resident will then have the option to grant or deny access
to the visitor by pressing a digit on their telephone.
In addition to the telephone entry, the AD-500 can grant access using
entry codes (up to 500 entry codes) at the local keypad. Interior and
exterior remote keypads are available.
2
All manuals and user guides at all-guides.com
Database Overview
Programming the AD-500 involves entering installation information into
the system's memory. The system uses this information as a reference
"database" to control the operation of the system.
Request-to-Exit Inputs
Up to 250 resident names and telephone numbers can be set. Each
resident entry is assigned a directory number. Directory numbers can be from two
to four digits in length (all will be the same length). The directory number is the
number a visitor would enter to have the system call the
resident.
RESIDENT DATA (UP TO 250 RESIDENTS)
FOR EACH RESIDENT: DIRECTORY NUMBER (2 TO 4 DIGITS)
NAME (UP TO 16 CHARACTERS)
PHONE # (UP TO 12 DIGITS)
Entry Code Data
Up to 500 entry codes can be set. Entry codes can be from two to six
digits in length (all will be the same length). An entry code is a number entered at
the
local
keypad
to
request
will activate. Each entry code can be set to restrict which relay
activates. Entry codes can also be set to toggle the relay output (output latches on
until the next time a toggle entry code is entered). Each entry code can be set for
a limited or unlimited number or uses.
ENTRY CODE DATA (UP TO 500 CODES)
FOR EACH CODE: ENTRY CODE (2 TO 6 DIGITS)
RELAY SELECTOR
TEMPORARY USAGE COUNT
access.