S S y y s s t t e e m m O O p p t t i i o o n n s s ( ( C C o o n n t t i i n n u u e e d d ) )
Speaker Tone on Relay Channel "A" Activation
The factory setting will not cause the speaker to sound a tone when access is
granted with Relay Channel "A". The tone can be turned on if desired.
1. If not already in Programming Mode, connect by telephone or use the
local keypad. Enter the master password and access programming.
2. Press:
3. Select the option for relay activation tone:
• Enter 0 to turn OFF the relay activation tone.
• Enter 1 to turn ON the relay activation tone.
4. Press:
5. Exit Programming Mode if all programming is complete.
Maximum Visitor Talk Time
Visitors will converse with residents over the telephone until the resident grants
or denies access. If the resident responds to the visitor's request by pressing
their telephone keys the system will hang up and release the telephone line. If for
some reason the resident does not press the telephone keys or does not hang
up, the system will automatically disconnect the visitor after 60 seconds. The
resident can extend the talk time by pressing the # key on their telephone. The
disconnect time can be adjusted from 15-255 seconds.
1. If not already in Programming Mode, connect by telephone or use the local
keypad. Enter the master password and access programming.
2. Press:
3. Enter the disconnect time in seconds (15-255).
4. Press:
5. Exit Programming Mode if all programming is complete.
S S y y s s t t e e m m U U t t i i l l i i t t i i e e s s
Several utility commands are available for the system. Utilities can be used to clear
memory, display system information, and control the relays.
Display Unit Number
In multi-unit installations the unit number of each AD-500 can be displayed.
1. If not already in Programming Mode, use the local keypad to enter the
master password and access programming.
2. Press:
3. The display will show the unit number for three seconds.
4. Exit Programming Mode if all programming is complete.
Manual Control of the Relays
For servicing or testing, each relay output can be controlled manually from the
local keypad while in Programming Mode.
1. If not already in Programming Mode, use the local keypad to enter the
master password and access programming.
2. Enter a command to control a relay:
• Press
to latch Relay Channel "A"
• Press
to latch Relay Channel "B".
• Press
to release Relay Channel "A"
• Press
to release Relay Channel "B".
3. The display will show the unit number for three seconds.
Deleting Database Entries
Sections of the database can be deleted individually. Exercise care when using
these commands, their effect cannot be reversed.
1. If not already in Programming Mode, connect by telephone or use the
local keypad. Enter the master password and access programming.
2. Enter a command to delete database selections:
• To delete all resident data:
• To delete all entry codes press: