SECTION 4
Blower Installation for Ducted
Range Hoods
NOTE: When reinstalling the blower, ensure
that the blower is facing the same way as
how you have chosen to duct it.
1.
With the opening of the blower facing
the direction you have chosen to duct
the hood, place the blower mounting
brackets (brackets on either side of the
blower) over the blower mounting studs
on the interior of the hood (Figure 6).
NOTE: Makes sure to support the blower in
position by hand until it is firmly secured to
the hood.
2.
Using the 4 nuts removed earlier, secure
the blower in place. Start the nuts by
hand first, then tighten with a 3/8" nut
driver or ratchet until they are fully
seated (Figure 6).
NOTE: FOR DUCTLESS INSTALLATIONS
ONLY, if you did not already do so in the
earlier steps, remove the vent insert from
behind the grill on the outside of the hood
(Figure 4).
3.
Plug the blower into the appropriate
connector on the side of the wire
compartment. It will only fit one way
(Figure 7).
Figure 7
SECTION 5
Installing the Range Hood
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
NOTE: If installing into existing construction and you will not have access to the ductwork
once the hood is in place, make ducting connections at this point. Refer to the Ducting
Section for instructions.
1.
Install the 4 mounting screws at the previously marked locations. Leave
approximately 1/8" clearance. Slide the hood in place through the keyhole slots and
align the front of the hood so that it is flush with the front of the cabinets. Tighten all
screws securely (Figure 8).
5084452 Rev. F 11-12
Horizontal
Studs
Vertical
Studs
Ductless
Studs
Figure 6
Connector
www.airkinglimited.com
1/8"
Figure 8
CAUTION:
DO NOT INSTALL CLOSER THAN 20 INCHES ABOVE COOKING SURFACE.
SECTION 6
Wiring
CAUTION:
ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE
WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE
UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
1.
Connect the loose White wires from the range hood to the White wire from the supply,
and the loose Black wires from the range hood to the Black wire of the supply. Connect
the ground wire (green or bare) from the supply to the green ground screw of the hood.
Use approved methods for all connections (Figure 9).
Neutral
(White)
From Hood
From Lamp
Figure 9
NOTE: DO NOT disconnect any wiring that has already been crimped with a wire connector
from the factory.
2.
Install the wire compartment cover and tighten screw. Make sure all wiring is securely
contained within the wire compartment.
SECTION 7
Ducting
CAUTION:
ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
WARNING:
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
1.
Connect the ducting to the hood's duct collar and damper. Secure in place using tape to
seal all joints (Figure 10).
Figure 10
Keyhole
Hot (Black)
From Hood
From Lamp
Ground
(Green or Bare)
3 of 12