When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6727902 Rev. D 10-16
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
f) Do not install in a ceiling with thermal insulation value greater than
R40.
g) This unit must be grounded.
h) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
i)
Read all instructions before installing or using exhaust fan.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
CAUTION:
FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing DL4S

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: DL4S, DL4SG, Exhaust Fan with Light DL4SH, DL4SGH READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2 SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 6" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: SECTION 1 ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. Preparing the Exhaust Fan NOTE: The ducting from this fan to the outside of the building has a strong effect on the air Unpack fan from the carton and confirm that all pieces are present.
  • Page 3 NOTE: There may be more than one white wire to be connected present. NOTE: The fan’s receptacle wires might need to be pulled outside compartment for connection. Screw Only pull the five loose wires outside of compartment. Additional wires will be present. NOTE: Unit must be grounded according to all local and national codes.
  • Page 4 SECTION 7 STANDARD MODELS: Plug the fan’s Motion quick connect motor cord into the Programming the Occupancy Sensor corresponding receptacle located on the wire compartment cover. This cord 1a. Setting the Occupancy Time Delay. This will set the amount will only fit one way into the receptacle of time the fan will continue to operate on high speed after the (Figure 10).
  • Page 5: Troubleshooting Guide

    SECTION 10 Fuse Follow the steps in SECTION 5 Wiring to gain access to the Use and Care fuse holder located inside the wire compartment. To replace CAUTION: MAKE SURE POWER IS SWITCHED OFF AT the fuse, squeeze the top an bottom of the fuse holder together SERVICE PANEL BEFORE SERVICING THE UNIT.
  • Page 6: Replacement Parts Diagram

    5S1202123 Blower Assembly 5S1250100 Fuse Harness Assembly 5S1250011 Light Lens 5S1239116 8 Watt LED Lamp 5S1250001 Specific to Model DL4S Qty. Description Replacement Part # Grill Assembly 5S1250105 Wire Compartment Assembly 5S1250105 Specific to Model DL4SG Qty. Description Replacement Part #...
  • Page 7: Ventilateur Combiner, Comprend Lumière Et Ventilation

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur combiner, comprend Modèles: DL4S, DL4SG, DL4SH, DL4SGH lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION NOTE: UN CONDUIT PLUS RIGIDE DE 6 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES SECTION 1 AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9: Couvercle Du Compartiment De Câblage

    REMARQUE : Il peut y avoir plus d’un fil blanc à connecter. Compartiment de Câblage Extérieur : Enlever la vis du couvercle du compartiment à câblage et mettre ce couvercle dans un endroit fiable (Figure 5). REMARQUE : Les fils du réceptacle du ventilateur pourraient nécessiter d’être tirés à l’extérieur du compartiment pour le raccordement.
  • Page 10: Programmation Du Capteur D'occupation

    SECTION 7 MODÈLES STANDARDS: branchez le Mouvement cordon de connexion rapide du moteur du Programmation du capteur d’occupation ventilateur dans la prise correspondante située sur le couvercle du compartiment de 1a. Réglage du délai d’occupation. Ceci va régler la durée de Ventilateur fil.
  • Page 11: Guide De Dépannage

    SECTION 10 Fusible Suivez les étapes de la SECTION 5 Câblage pour accéder au Utilisation et entretien porte-fusible situé à l’intérieur du compartiment de câblage. ATTENTION : Pour remplacer le fusible, pressez le haut et le bas du porte- VOUS ASSURER QUE L’ALIMENTATION fusible ensemble tout en tournant le plus gros morceau dans EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER une direction opposée aux languettes (Figure 13).
  • Page 12: Diagramme Des Pièces De Remplacement

    Assemblée de la Soufflante 5S1250100 Assemblage du harnais de fusible 5S1250011 Objectif de lumière 5S1239116 Lampe de 8 watts à LED 5S1250001 Particularités de modèle DL4S # de pièce de Qté. Description remplacement Assemblée de Grille 5S1250105 Assemblée du compartiment du fil 5S1250105 Particularités de modèle DL4SG...

Ce manuel est également adapté pour:

Dl4sgDl4shDl4sgh

Table des Matières