4.
Reinstall the lens into the grill (Figure 11).
5.
Restore power and test your installation.
SECTION 7
Use and Care
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE
PANEL BEFORE SERVICING THE UNIT.
CAUTION:
ALLOW BULB TO COOL BEFORE REPLACING.
Changing the Lamp
Remove the light lens by squeezing at the tabs and pulling down (Figure
12). Remove lamp by gently twisting the lamp base counterclockwise while
applying outward pressure. Installation is the reverse of removal. Replace
with Air King model 26SBL or a compatible GU24 26 watt self ballasted lamp.
Trouble
1. Fan does not operate when the switch is on.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal
A210572219 Rev. D 12-12
Cleaning the Grill
Remove grill and use a mild detergent, such as dishwashing liquid, and
dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING
POWDERS. Completely dry grill before reinstalling. Refer to instructions in
Section 6 Finishing the Installation, to reinstall grill.
Cleaning the Fan Assembly
Unplug the motor cord from receptacle. Wipe all parts with a dry cloth or
gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
Plug the motor cord back in and restore power.
Troubleshooting Guide
Probable Cause
1a.
A fuse may be blown or a circuit tripped.
1b.
Connector plug from motor is not plugged in. 1b.
1c.
Wiring is not connected properly.
1d
Motor has stopped operating.
2.
Obstruction in the exhaust ducting.
3a.
Motor is loose.
3b.
Fan blade is hitting housing of unit.
www.airkinglimited.com
Tabs
Figure 12
Suggested Remedy
1a.
Replace fuse or reset circuit breaker.
Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c.
Turn off power to unit. Check that all wires are connected.
1d.
Replace motor.
2.
Check for any obstructions in the ducting. The most common are bird
nests in the roof cap or wall cap where the fan exhausts to the outside.
3a.
Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b.
Call your dealer for service.