Troubleshooting
What if I am having a problem with the humidifier?
If you have difficulty with the humidifier, please try the following suggestions. Most problems can be corrected
quickly and easily.
Problem
What To Look For
Low humidity
Furnace blower not
operating
Rapid air changes or
drafts
High humidity
Condensation on walls
Heavy condensation on
windows
Replace Pad
This is the yearly
light is blinking
maintenance reminder to
(HE150/HE250/
replace the pad inside the
HE300)
humidifier
Service light is on
The damper inside the
(HE150/HE250)
bypass has failed to open
completely or the air
proving switch sensed a
lack of air movement
Service light is on
The fan motor has failed
(HE300)
or the air proving switch
sensed a lack of air
movement
Humidifier 69-2414EF—01
All manuals and user guides at all-guides.com
What To Do
1.
Reset circuit breaker or check for blown fuse.
2.
Check that the furnace power is on.
3.
Check the humidity control setting.
4.
Call a professional heating contractor
1.
Keep doors and windows closed.
2.
Close fireplace damper when not in use.
3.
Keep exhaust fan running time to a minimum.
4.
Seal around doors and windows.
1.
Turn off humidity control and water until condensation is completely
evaporated.
1.
Turn humidity control down low enough to eliminate condensation
caused by moisture. If moisture persists, more ventilation is needed.
1.
Replace the pad for your humidifier model.
2.
See "Replace the humidifier pad" section for details.
3.
Once pad is replaced, press the RESET button under the wire cover.
1.
Press the RESET button under the wire cover.
2.
If fault persists, call an HVAC professional.
1.
Press the RESET button under the wire cover.
2.
If fault persists, call an HVAC professional.