3.2
Opening time adjustment (trimmer A) (ONLY PCM130)
Adjust the trimmer to reduce the massimadurata drive motor in the event of failure to report the
limit-stop.
3.3
Electronic clutch adjustment (trimmer A) (ONLY PCM100)
This adjustment that must be done on a weight and strength of the cancelation of inertia that
acquiresworks on the thrust force of geared-motor: this force must cause the moving of the gate, and for
ensure his arrest in that case you should put an obstacle to his race.
Under provisions of the law, the adjustment must be made so that the thrust force of the gate is equal
to 15Kg; it means that a force equal to 15Kg, in opposition to the movement of the gate, must stop the gate
during its movement.
To set this adjustment, we suggest you to use an instrument called linear dynamometer.
3.4
Time of pause adjustment (trimmer B)
If the central unit is setted on Automatic operating or Automatic operating for Parks, you
must adjust the time of pause that must elapse between the end of the opening and the start of
the closing of the gate.
3.5
Electronic Brake / Slowing Down (trimmer C) (ONLY
PCM100)
Turned in anticlockwise direction:
Electronic brake:
Slowing down:
Turned in clockwise direction:
Electronic brake:
Slowing down:
NOTE : The slowdown occurs after two complete cycles of opening and closing
3.6
Control LEDs
Below is the meaning of the LEDs present on the boards PCM100 (see page 5) and
PCM130 (see page 6).
LED
LED
LED Button P1
LED Button P2
LED photocell
1 status
LED photocell
2 status
LED opening
limit stop status
LED closing
limit stop status
LED STOP Status
LED microprocessor
diagnosis
All manuals and user guides at all-guides.com
disabled
enabled at the end of opening / closing
enabled, reduces the movement after the limit/stop is
activated.
disabled
COLOR
FTC
green
green
FX30D
red
FX40D
FX30D
red
FX40D
red
red
yellow
green
ON
BLINKING
Pulse on input A
(total opening)
Pulse on input B
(partial opening)
Photocell 1
st/by
engaged
st/by
Photocell 2
st/by
engaged
st/by
st/by
Anomaly
Normal operating
OFF
st/by
/
st/by
/
Photocell 1 engaged
Photocell 1 engaged
Photocell 2
engaged
/
STOP command active
Anomaly