Télécharger Imprimer la page

Hiltron security PCM100 Manuel Pour L'utilisateur page 20

Centraled'automatison pour portail coulissant

Publicité

Les langues disponibles

Les langues disponibles

PCM100 / PCM130 - User Manual
1
Introduction
1.1
Central Unit Description
PCM100 and PCM130 Central Unit for sliding gates operates a geared-motor 230Vac
700VA max, as MS100 or MS200 producted by HILTRON and geared motor MS200T (380Vac
550W), by an electrical clutch, realized with a microprocessor of last generation. PCM100 and
PCM130 Central Unit are furnished with a sophisticated circuit of auto-diagnosis that controls
costantly the operation of the system and connected devices; in case of troubles, the circuit
stops all central unit operation. The monitoring of peripheral operating connected to the central
unit is displayed by LEDs placed on the circuit. Moreover, PCM100 Central Unit are furnished
also with a electrical brake is equipped with electronic brake reduces stopping distances of the
gate to guard the stop of geared-motor. In place of the brake, the slowing down function is
activated 3 seconds before the limit stop that which allows the combination of the gate. All
movements of the gate, are preceded by 2 seconds from activation of the flasher.
The PCM100 PCM130 and are CE marked as they are compliant with the EMC
2006/95/CE e 2004/108/CE.
Control inputs: STOP input; PULSE A: total opening, PULSE B: partial opening (pedestrian passing), photocells, limit stop
Built-in interface for BIRD receiver
Peripheral monitoring by LEDs
Programmable operating modes: Automatic, Semiautomatic, Step-by-step with automatic closing, Step-by-step with STOP
Power supply voltage
Max power for geared motor
Service output voltage
Max current consumption
Max current supplied on service output
Box protection level
Opening/closing time
Pause time
External box
Operating temperature
Dimensions (W)
Dimensions (H)
Dimensions (D)
Weight
20
All manuals and user guides at all-guides.com
PCM100
"SLOWING DOWN" function with "BRAKE"
trimmer at minimum
Function "BRAKE" adjustable by trimmer with
exclusion to minimum
Regulation trimmer: "BRAKE", "PAUSE",
"CROWD FORCE"
4 ÷ 60sec.
Predisposition for security photocells FX30, or others
230V~ ±5% 50Hz
700VA
24V~ ±5% max 0,3A
6VA
125mA
IP44
90sec. Max
ABS
-25°C ÷ +55°C
127mm
138mm
57mm
0.075Kg
security
PCM130
Regolation of "OPENING" and PAUSE by
trimmer
4KW
11VA
IP54
4 ÷ 130sec.
195m
250mm
100mm
1Kg

Publicité

loading

Ce manuel est également adapté pour:

Pcm130